Cleaning Procedure
NITROSET® Tool Full Cleaning Procedure
It is recommended that the NITROSET® tool be cleaned every day after use.
Proper maintenance and cleaning of the tool enables the tool to operate at
peak performance.
1.
First, be sure all fastener assemblies and debris are ejected from the tool by
resetting it pointed away from yourself or any bystanders.
2.
Remove the muzzle by unscrewing it from the tool shank. Then, remove the
end cap and disassemble the entire tool following the tool disassembly
instructions (Page 14).
3.
Empty the debris cup.
4.
To clean, you should use diluted industrial cleaner and degreaser similar to
Strike-Hold or other similar non-oil base degreaser to spray or wipe the tool
surface. Allow contact time of 3 to 5 minutes before scrubbing. Rinse with
water and wipe it dry with towel or paper.
5.
Re-assemble the tool (Page 15).
Interim Cleaning Procedure
1.
Empty the debris cup after every 500 fastenings, or as needed to optimize
performance.
2.
A liquid shot of degreaser lubricant at approximately every 500 to 1000
fastenings is recommended to maintain a smooth operation.
3.
This will help tool performance and actuating consistency, making your
end-of-day cleaning easier.