Elkay EZ Serie Manual De Instalación, Cuidado Y Utilización página 7

Tabla de contenido

Publicidad

7/16" BOLT HOLES FOR
FASTENING UNIT TO WALL
Fig. 5
1) Remove two (2) mounting screws with 5/32" allen wrench holding top cover to Bottle Filler (See FIG. 6). Remove top cover. Note do not discard mounting
screws, they will be needed to reinstall top cover.
2) Remove wall mounting plate from Bottle Filler. Place Wall plate against wall on top of EZ basin. Center the wall plate side to side with the EZ basin. Mark
the six (6) mounting holes with a pencil (See FIG. 2 or 3).
3) Remove wall mounting plate from wall. NOTE: Mounting plate MUST be supported securely. Add fixture support carrier if wall will not provide adequate
support.
4) Install wall mounting plate to wall using six (6) 7/16" obround mounting holes (mounting bolts not included) (See FIG. 5). Use appropriate fasteners for
your wall type.
5) Locate plastic bushing (provided) and place in basin hole by pushing into hole until it snaps into place. This bushing protects the water line, wire(s),
and power cord from sharp edge of basin. This part must be used.
6) Place Drain Mat into position on the bottom of the Bottle Filler Unit.
7) Fish the purple wire (single units) or the purple and yellow wires (two-level units) up through basin hole.
8) For Single Model installations: Attach the purple wire from cooler to the purple wire on the back of the unit, (Note yellow wire is not used).
8a) For Two-Level model installations: Attach the purple and yellow wires from coolers to the purple and yellow wires on the back of the unit, purple to
purple, yellow to yellow.
9) Remove 3/8" to 1/4" reducing union from end of waterline, (do not throw away it will be needed later). Lay Bottle Filler on water cooler basin and cut
insulation from tube even with bottom of unit, remove this insulation from the 3/8" tube, but do not discard. Fish the power cord, and waterline through
the hole on top of water cooler created from the "Water Cooler Preparation" section. NOTE: To prevent scratching the basin place a towel or soft cloth over
the entire basin when working above it.
10) With the power cord, wire(s), and waterline through hole on top of water cooler place Bottle Filler on the three (3) angled tabs protruding from the wall
mounting plate, installed on wall (See Fig. 5). Make sure rubber Drain Mat is installed properly on bottom of Bottle filler.
11) once Bottle Filler is installed on wall plate tabs, drain mat, water line, wire(s) and power cord are installed properly, push top of Bottle Filler toward
wall and line up top cover two (2) holes.
12) Reinstall Top Cover on Bottle Filler (See FIG. 6) with two mounting screws from step 1 above. Caution do not over tighten screws.
13) Install remaining tube insulation to the water line from bottle filler, connect Bottle Filler waterline inside of the water cooler by
connecting the 3/8" water line with the 3/8" to 1/4" union and short piece of poly tube that was previously installed to the tee.
14) Install filter cartridge, remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter
clockwise. NOTE: If existing plumbing roughin locations (Drain, Water In, Electric Supply) do not allow the filter to be mounted inside the cooler cabinet
the filter can be installed horizontally below the unit. A retrofit kit is available to mount the filter beneath the cooler.
15) Turn water supply on and inspect for leaks. Fix all leaks before continuing.
16) Once unit has been inspected for leaks and any leaks found corrected plug Bottle Filler and EZ unit into wall. Be sure to reinstall fuse to the circuit or
switch the circuit breaker back to the "ON" position.
17) Once power is applied to Bottle Filler, the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter.
18) Verify proper dispensing by placing cup, hand, or any opaque object infront of sensor area and verify water dispenses. Note: the first intitial dispenses
might have air in line which may cause a sputter. This will be eliminated once all air is purged from the line.
19) Once unit tests out, install Lower Panel back on EZ water cooler(s). Units are now ready for use.
Note: Screw the locknut hand tight to seal
Fig. 7
EZSTLG8WS*1A,
TOP COVER
UNIT CENTER LINE
BOTTLE FILLER INSTALLATION
Page 7
LZSTLG8WS*1A
26
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE IS SECURED
TUBE TO ATTACH
IN POSITION
A
B
MOUNTING
SCREWS
Fig. 6
PUSH IN COLLET
TO RELEASE TUBE
C
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
Fig. 8
RELEASE TUBE
0000000740 (Rev. B - 8/13)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lz serieEzstlg8ws1a serieLzstlg8ws1a serie

Tabla de contenido