DIY Analyzer
3. Erasing the errors
Erasing the errors can be done only if the drive or impeller motor is needed to be replaced – press
on the 'test' button for a few seconds while the motor unit is connected to the Analyzer and before
testing it in the water.
4. Calibrating the Analyzer
After 200 Analyzer tests, the Analyzer will not stop beeping, you need to calibrate the Analyzer.
Connect the MU PCB card cable and the MU cable into the back of the Analyzer and press 'test':
Connect the MU PCB card cable and the MU
cable into the back of the Analyzer
Note:
It is recommended to have the robot work in a testing pool or water tank for one full cycle to ensure
everything is running properly.
If you have any questions, please contact us. We will be happy to help you.
Maytronics Technical department team
The cables
connected into the
back of the Analyzer
Press on the 'start'
button for a few seconds