Installation Instructions; Window Requirements; Preparation Of Cabinet - KENMORE ELITE 580.77157710 Manual De Uso

Aire acondicionado inteligente para habitación
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Window Requirements

Size
NOTE: Secure all supporting parts to firm wood,
masonry, or metal.
This room air conditioner is designed for installation in
standard double-hung windows with actual opening
widths from 29" to 41".
The upper and lower window sash must open
sufficiently to allow a clear vertical opening of 19"
from the bottom of the upper sash to the inside sill.
The height offset between the inside sill and outside sill
must be less than 1 ¼".
29" to 41"
19" min
Clearance
Proper clearance enhances the cooling efficiency of the
product.
If a storm window presents interference, fasten a 2"
1
wide wood strip to the inner window sill across the
full width of the sill. The wood strip should be thick
enough to raise the height of the window sill so that
the unit can be installed without interference by the
storm window frame.
(See drawing.) The top of the wood strip on the
2
inside sill should be approximately ¾" higher
than the storm window frame or wood strip on the
outside sill to help condensation to drain properly to
the outside.
If necessary, install a second wood strip (same
3
thickness as first strip) across the full width of the
outer sill, flush against the back of the inner sill.
Wood Strip Mounted
on Top of Inner Sill
Inner Sill
Wood Strip
Indoors

INSTALLATION INSTRUCTIONS

¾"
Clearance
Storm
Window Frame
Outer Sill
Outdoors

Preparation of Cabinet

Remove the 4 screws which fasten the cabinet at
1
both sides and at the back. (2 of the screws will be
used later to refasten the sides of the cabinet to the
unit.)
Shipping
Screws
Slide the unit from the cabinet by gripping the base
2
pan handle and pulling forward while bracing the
cabinet.
CAUTION
The unit is heavy. To prevent injury, use proper lifting
techniques when pulling unit forward from cabinet.
Obtain assistance from another person if possible.
Cut the window sash seals (Foam-PE) to the
3
proper length. Peel off the backing and attach
the adhesive-backed foam to the underside of the
window sash and the bottom of the window frame.
Insert the lower curtain panel guides into the bottom
4
of the cabinet. Insert the guides so that the flange
faces to the rear of the cabinet.
8
Foam-PE
(Adhesive backed)

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

580.77187710580.77247710

Tabla de contenido