8. INSTALLATION
•
Begin by placing the kiosk on a flat, level surface. Remove the cardboard packaging and the
metal sheets that support the packaging. (Fig. 02)
•
Before entering the kiosk, block the wheels to prevent it from moving. (Fig. 03)
•
Open the door and, before opening the top of the kiosk, enter inside and remove the
transport safety hooks. (Fig. 01)
•
Make sure the voltage and frequency of the kiosk coincide with the electrical installation.
•
Connect the exterior electrical plug to the installation with the corresponding earth
connection.
•
Actuate the thermomagnetic switch of the main switchboard, the differentials and the
isolating switch. (Fig. 04)
•
Proceed to raise the top of the kiosk, using the UP-DOWN control. (Fig. 05)
•
Clean the kiosk before starting it up.
9. MAINTENANCE
•
Exterior maintenance of the kiosk is limited to cleaning only.
•
When the machine is not in use, protect it from inclement weather and direct sunlight.
•
Polish the paint on the outer surface when it appears worn (according to use and
emplacement of kiosk).
10. IDENTIFYING DAMAGES
Fault
The lights do not come on
The top part does not lift up
No water comes out of the tap
11. ELECTRICAL INSTALLATION
Cause and/or solution
Connect the corresponding thermomagnetic switch
Connect the corresponding thermomagnetic switch. If it still fails
to work and you want to raise or lower the top part
lower cover of the mast and do it manually by using the handle,
!
when the operation is complete DO NOT FORGET TO REMOVE
THE CRANK AND PUT THE COVER BACK (Fig. 06).
Check there is water in the tank and that the pump is submerged
8
,
remove the