Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GETTING TO KNOW YOUR ACR
Full-Color Touchscreen Interface
Main Power Switch and Circuit
Breaker Switches
Power Input Receptacles
Heater Output Receptacles
®
© BriskHeat
Corporation. All rights reserved.
®
ACR
3 Hot Bonder
®
3 HOT BONDER
ype J Thermocouple
Inputs Vacuum Hose Inputs, Vacuum
Adjustments, and Vacuum Pump
Switch.
Printer and Printer Feed Button
USB Data Port
5

SPECIFICATIONS

General

Single or dual zone

8.4" (213mm) touch screen with easy-to-use interface

USB port for data transfer

Input ground fault interrupter breaker protected

Audible and visual alarms for high and low temperature / vacuum limits
Power

Input Voltage: 100-130VAC, 200-240VAC

MAINS supply voltage fluctuations up to ±10% of the nominal voltage

Transient overvoltages typically found on a Category II power source: i.e. a lighting circuit

Frequency: 50/60Hz

30 amps maximum per zone

Maximum output rating: 240VAC, Single Phase
Environment

Intended for use in dry environments. Do not expose to spray

Altitude up to 6562ft (2000m)

Storage temperature range: -4°F to 140°F (-20°C to 60°C)

Operating temperature range: 41°F to 104°F (5°C to 40°C)

Maximum relative humidity: 80% for temperatures up to 88°F (31°C) decreasing linearly to
50% relative humidity at 104°F (40°C)

Pollution Degree 2 (Normally only non-conductive pollution occurs, however a temporary
conductivity caused by condensation must be expected)
Vacuum

Pressure: 27-28in Hg (13.26-13.75PSI)

Flow: 5.7 scfm (Vacuum Venturi)
0.9 scfm (Electric Vacuum Pump)

Ability to manually adjust pressure for each zone
Temperature Control

Cures up to 1400°F (760°C)

10 thermocouple sensor inputs per zone

Accepts mini Type J thermocouple connectors
®
© BriskHeat
Corporation. All rights reserved.
®
ACR
3 Hot Bonder
6

Publicidad

Tabla de contenido
loading

Tabla de contenido