Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
Disconnect power and release
all pressure from the system
before attempting to install, service,
relocate or perform any maintenance.
1. Locate the air flow direction arrow
(See Figure 2, detail). This arrow
shows the direction of the air flow.
2. Securely mount the filter in a vertical
position as close as possible to air
tool connection.
3. Verify the arrow points in the direction
of the air flow. (See Figure 2.)
4. Install the unit with the same pipe
size as the piping in use. Avoid using
unnecessary fittings, couplings, etc.,
that restrict airflow. Use PTFE tape on
all threads.
5. Connect the air supply to the inlet
port.
Figure 2 - detail showing location of flow
direction arrow
Operation
Before pressurizing system, make certain
the bowl is securely locked in place by
pushing it into the filter body and turning
clockwise to lock.
Maintenance
Release all pressure before
attempting to install, service,
relocate or perform any maintenance on
the air system. Personal injury and/or
property damage could occur.
removing the bowl. Personal injury and/
or property damage could occur. If bowl
is difficult to remove, it may be under
pressure.
1. Inspect and replace cracked,
2. Replace or clean filter element
Flow
direction
arrows
3. Drain bowls at least once per work
4. Before placing the unit in service,

technIcal seRvIce

For information regarding the operation or
repair of this product, please call 1-855-
504-5678.
www.campbellhausfeld.com
damaged or deteriorated seals. Wipe
bowls with a soft, dry cloth to clean.
If bowl is damaged, unit must be
replaced.
periodically. Remove the filter element
and tap filter on a hard surface or use
an air gun to blow out residual dirt.
shift. Pressure should be regulated
down to 30 psi max before drain is
opened. To avoid spray or splatter,
cover bottom of filter with a cloth and
turn in the manual drain valve.
make sure the bowl is reinstalled and
securely locked in place.
PA211000AV
Always depressurize
the unit before
3

Publicidad

Tabla de contenido
loading

Tabla de contenido