READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELEC-
TRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended
by the manufacturer. If you have ques-
tions, contact the manufacturer at the
address or telephone number listed in
the warranty.
2. Before servicing or cleaning unit, switch
power off at service panel and lock the
service disconnecting means to prevent
power from being switched on acciden-
tally. When the service disconnecting
means cannot be locked, securely fasten
a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring
must be done by a qualified person(s)
in accordance with all applicable codes
and standards, including fire-rated con-
struction codes and standards.
4. Sufficient air is needed for proper com-
bustion and exhausting of gases through
the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow
the heating equipment manufacturer's
guideline and safety standards such
as those published by the National
Fire Protection Association (NFPA),
and the American Society for Heating,
SPECIFICATIONS
MODEL
VOLTS
EB15
120
PLAN THE INSTALLATION
ALL INSTALLATIONS
1. Locate the blower so the length of the
duct run and number of elbows are kept
to a minimum.
2. Where possible, blower
should be centered be-
tween wall studs or roof
rafters.
3. Avoid pipes, wires, or
other ductwork that may
be running through the
wall.
4. Attach mounting plate to
top of hood.
5. Install 10" dia. ductwork
and 120 VAC house
wiring between blower
location and hood location.
WARNING
5. When cutting or drilling into wall, or ceiling,
6. Ducted fans must always be vented to the
7. To reduce risk of fire, use only metal
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not
2. To avoid motor bearing damage and noisy
3. Please read specification label on product
4. Electrical circuit, including speed control,
AMPS
CFM
4.3
1500
MODEL EB15
EXTERIOR BLOWER
SOFFIT
WALL HOOD
CANOPY
10"
18"
21" or 24"
2
Refrigeration and Air Conditioning En-
gineers (ASHRAE), and the local code
authorities.
do not damage electrical wiring or other
hidden utilities.
outdoors.
ductwork.
use to exhaust hazardous or explosive
material and vapors.
and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power
unit.
for further information and requirements.
(if used), must be rated 6 AMPS minimum.
INSTALLER: Leave This Manual With
The Homeowner.
HOMEOWNER: Use And Care Infor-
mation On Page 6.
DUCT SIZE
10 " DIA.
SOFFIT
WALL HOOD
CANOPY
10" ROUND
DUCT
ROUGH-IN
PLATE
TYPICAL
or
ROOF MOUNTED IN-
STALLATION
10" ROUND ELBOW
10" ROUND DUCT
MODEL
EB15
EXTERIOR
BLOWER
10"
or
18"
ROUGH-IN
PLATE
21" or 24"
TYPICAL WALL
MOUNTED IN-
STALLATION