1. Inspect heater components for possible
shipping damage. If any is found, imme-
diately notify dealer. Check to make sure
that all components are included with your
heater (see pages 8 and 9).
2. For 15,000 BTU Models Remove wing
nut attaching regulator assembly to the
burner. Use wing nut and washers to at-
tach tank bracket to the burner assembly
as shown in Figure 1.
Burner Head
Assembly
Washers
Wing Nut
Tank
Bracket
Figure 1 - Attaching Single Burner
Assembly to Tank Bracket
1. Check heater for damage. If heater is
damaged, promptly inform dealer where
you bought heater.
2. Follow all of the safety and operating
precautions.
3. Check the "O" ring on the POL before
each use. Replace "O" ring if there is any
sign of wear or damage.
4. Make sure heater regulator knob is in the
OFF position.
5. 30,000 Btu Models Only Attach the
heater to the guard on the propane/LP
cylinder as shown in Figure 3. Tighten
knob on tank bracket to secure heater.
6. For All Models Connect regulator to pro-
pane/LP cylinder by rotating nut counter
clockwise into the propane/LP cylinder
valve outlet and securely tighten with a
wrench.
160220-01B
ASSEMBLY
3. For 30,000 BTU Models Using 2 screws
from hardware package, attach tank
bracket to the burner assembly as shown
in Figure 2.
Tank
Bracket
Figure 2 - Attaching Double Burner
OPERATION
Tank
Bracket
Knob
Propane/LP
Tank
www.usaprocom.com
Screw
Assembly to Tank Bracket
Regulator
Figure 3 - Attaching Heater to
Propane/LP Tank
Burner Head
Assembly
5