Installation and Operation manual G.A.S.-pro
7. Troubleshooting:
- If the operating test does not trigger an alarm, check the wiring using the terminal diagram.
- If, after initial switch-on and the end of the warm-up phase, an alarm sounds immediately,
the sensor may not have been stored properly, and is therefore heavily soiled. Repeat the
switch-on procedure several times until the alarm no longer sounds.
- If a problem other than the one described occurs, please check the wiring using the
terminal diagram. If the fault is not in the wiring, please contact your dealer or our
technical hotline.
Technical specifications:
Power supply:
Current consumption:
Weight:
Detection:
Delivery scope:
24 month warranty from date of purchase
To prevent damage to the device, use only genuine Thitronik accessories.
Otherwise the warranty will be voided!
Compatible accessories:
External siren Art. No.:
Additional sensor Art. No.:
CO sensor Art. No.:
External LED Art. No.:
Back up siren Art. No.:
9-30 VDC
approx. 10 mA (central unit)
approx. 75 mA (per sensor)
approx. 40 mA (CO sensor)
approx. 140 g
from 50 ppm narcotic gas, propane,
butane
from 300 ppm carbon monoxide
(optional)
Central unit incl. sensor, alarm sticker, manual
and mounting materials.
100191