MODELS
ELEMENTS
VOLTAGE
MAX kW
kW PER ELEMENT
MAX AMPERAGE DRAW
REQUIRED BREAKERS
REQUIRED WIRE GAUGE
Circuit Break #1
L1
BLACK
HA008240 – HA011240 – HA013240
requires 1 breaker and 1 set of wires
HA018240 requires 2 sets of breakers and wires
HA024240 – HA027240 require 3 sets of breakers and wires
When using 208V service for these units instead of 240V you must change the jumper setting to ensure proper
unit functionality. Using a 208V service will give you 75% capacity.
Model
New Jumper Setting (Surface Mount)
Electrical Specifications by Model
HA008240
HA011240
1
2
240 V
240 V
8 kW
11 kW
8 kW
5.5 kW
33 AMPS
46 AMPS
1 x 40 AMP
1 x 50 AMP
1 x 8 AWG
1 x 6 AWG
Circuit Breaker #2
L1
L2
BLACK
RED
HA036240 requires 4 sets of breakers and wires
208V Jumper Setting
HA008240
HA011240
8
HA013240
HA018240
2
2
240 V
240 V
13 kW
18 kW
6.5 kW
9 kW
54 AMPS
75 AMPS
1 X 60 AMP
2 X 40 AMP
1 x 6 AWG
2 X 8 AWG
Wiring Diagram
Circuit Breaker #3
L1
L2
BLACK
RED
HA013240
HA018240
5
7
7
6
HA024240
HA027240
3
3
240 V
240 V
24 kW
27 kW
8 kW
9 kW
100 AMPS
112.5 AMPS
3 x 40 AMP
3 X 40 AMP
3 x 8 AWG
3 X 8 AWG
Circuit Breaker #4
L1
L2
BLACK
RED
HA024240
HA027240
5.5
7
HA036240
4
240 V
36 kW
9 KW
150 AMPS
4 X 40 AMP
4 X 8 AWG
L2
RED
HA036240
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ha011240Ha013240Ha018240Ha024240Ha027240Ha036240

Tabla de contenido