Performance Data Sheet (continued):
PQC2FS with PQCSED and PQCCRBL Filters
Average Influent
Substance
Challenge Concentration
NSF Standard 42/53
Chlorine
2.0 mg/L ± 10%
Cyst
≥ 50,000 /mL
pH 6.5
Lead
0.15 mg/L± 10%
pH 8.5
Particulate Class I
Flow Rate = 0.5 gpm (1.9 lpm) Capacity = 500 gallons (1,890 L) or 6 months
Tested by NSF International according to NSF/ANSI Standard 42, 53 and CSA B483.1.
1
Troubleshooting Guide:
Problem
Water dispenser is leaking
No hot water
No cold water
Water dispenser is not dispensing
water
Alarm is beeping continuously
Attention: Do not return this product to the store.
Should service be required or you have any questions regarding how to use your PUR product, please contact Customer Service at:
1-877-447-4768 or customerservice@ghpgroupinc.com
Manufactured and warranted by GHP Group Inc.
USA: 6440 W. Howard St. Niles, IL 60714-3302
Canada: 271 Massey Rd. Guelph, Ontario, N1K 1B2
11
Percent Reduction
Requirement
≥ 50%
≥ 99.95%
0.010mg/L
10,000/mL
≥ 85%
Possible Cause
Check all water line connections for
leaks
Filter not properly secured and locked
Drain cap and plug are not secure
Insufficient water levels in the reservoir Make sure all water shut-off valves are open.
The unit is unplugged
Hot water switch is "OFF"
Temperature limit switch tripped
The circuit breaker in your home is
tripped or the water dispenser fuse
(11) is blown
The unit is unplugged
Cold water control needs to be
adjusted colder
Water shut-off valves are closed
Water leakage detection system is
activated
Percent Reduction
1
97.4%
99.99%
99.7%
99.7%
99.6%
Solution
Repair water line connections and make sure blue locking "c-clips" are
installed on water lines.
Secure filter and lock.
Ensure drain plug is secure and tighten drain cap.
Plug in the power cord.
Make sure the hot water switch is "ON"
The temperature limit switch will re-set automatically when the
temperature of the water drops.
Reset the breaker or replace the water dispenser fuse.
Plug in the power cord.
Adjust cold water control between L (warm) and H (colder) levels to
achieve desired temperature.
Open all water shut-off valves.
Refer to Water Leakage Detection System instructions in the manual.