Before calling for service, try the suggestions below to see whether you can solve your problem without outside help.
Air conditioner will not operate
A WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
The power supply cord is unplugged.
Plug into a grounded 3 prong outlet. See " electrical
Requirements."
Time-delay fuse or circuit breaker of the wrong
capacity is being used.
Replace with a time-delay fuse or circuit breaker of the
correct capacity. See" electrical Requirements".
The power supply cord has tripped (Reset button has
popped out).
Press and release RESET (listen for click; Reset
button will latch and remain in) to resume operation.
A household fuse has blown, or a circuit breaker has
tripped.
Replace the fuse, or reset the circuit breaker. See
"Electrical Requirements".
The On/Off button has not been pressed.
Press ON/OFF.
The local power has failed.
Wait for power to be restored.
Air conditioner blows fuses or trips circuit breakers
Too many appliances are being used on the same circuit.
Unplug or relocate appliances that share the same circuit.
You are trying to restart the air conditioner too soon after
turning off air conditioner.
Wait at least 3 minutes after turning off air conditioner before
trying to restart the air conditioner.
You have changed modes.
Wait at least 3 minutes after turning off air conditioner
before trying to restart the air conditioner.

TROUBLESHOOTING

Air conditioner power supply cord trips (Reset button
pops out)
Disturbances in your electrical current can trip (Reset
button will pop out) the power supply cord.
Press and release RESET {listen for click; Reset button will
latch and remain in) to resume operation.
Electrical overloading, overheating, cord pinching or
aging can trip (Reset button will pop out) the power
supply cord.
After correcting the problem, press and release RESET
{listen for click; Reset button will latch and remain in) to
to resume operation. If the power cord fails to reset, contact a
service technician.
NOTE: A damaged power supply cord must be replaced with a
new power supply cord obtained from the product manufacturer
and must not be repaired.
Air conditioner seems to run too much
Is there a door or window open?
Keep doors and windows closed.
The current air conditioner replaced an older model.
The use of more efficient components may cause the air
conditioner to run longer than an older model, but the total
energy consumption will be less. Newer air conditioners do
not emit the " blast" of cold air you may be accustomed to
from older units, but this is not an indication of lesser cooling
capacity or efficiency. Refer to the efficiency rating (EER) and
capacity rating (in Btu/h} marked on the air conditioner.
The air conditioner is in a heavily occupied room, or heat­
producing appliances are in use in the room.
Use exhaust vent fans while cooking or bathing and try not
to use heat-producing appliances during the hottest part of
the day. Portable air conditioners are designed as
supplemental cooling to local areas within a room. A higher
capacity air conditioner may be required, depending on the
size of the room being cooled.
Air conditioner runs for a short time only, but room is not
cool
Set temperature is close to room temperature.
Lower set temperature. See "portable Air Conditioner Use ".
Display error code
if the unit display error code ES, it is water full in the unit,
you should drain the water, see "Draining the air
conditioner". After draining, you can operate the unit again.
if the unit display error code E1/E2/E3/E4/EA, please contact
customer service.