Descargar Imprimir esta página

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 171

Malfunctions

Malfunctions
Blue LED on the mixer tap
is not lighting up
Water does not run when
the sensor is activated
Hot water mode is
not functioning
Cold and/or warm water
is not running
The set water quantity
for filter or hot water is
significantly different
Status LED on the boiler
is glowing orange
46
Possible causes
- Mixer tap is not receiving
electricity
- The volume wheel is at "0"
- Connecting hoses
are kinked
- Connecting hoses are
wrongly attached
- The volume wheel is at "0"
- Filter head is connected in
the incorrect flow direction
- Electronic devices are in
front of the sensor
- The volume wheel is at "0"
- Connecting hoses
are kinked
- Connecting hoses are
wrongly attached
- Malfunctions in
the control box
- System error in the boiler
Error correction
- Connect the power supply unit of the control
box to the mains electricity
- Check the connections on the control box
- Turn the volume wheel and set
an amount > "0"
- Connect hoses without kinks
- Connect the hoses according to
the assembly instructions
- Turn the volume wheel and set
an amount > "0"
- Check whether the filter cartridge has
been connected against the flow direction,
and change the flow direction
- Remove electronic devices
- Turn the volume wheel and set
an amount > "0"
- Connect hoses without kinks
- Connect the hoses according to
the assembly instructions
- Unplug the power supply of the control
box for one minute, then connect it to
the mains again
- Unplug the power supply of the boiler for one
minute, then connect it to the mains again

Publicidad

loading