Tap mode
• Regardless of the position of the
Forward/Reverse lever (E), every time
the trigger switch is pressed, the drill
switches between "forward" and
"reverse".
Check the "FWD" and "REV" lamps when
working.
The lamp lights up in accordance with
"forward" or "reverse".
NOTE:
• When using the Tap mode function,
the tap drill may be damaged, so set
the clutch handle at position 1 before
use.
• Tip tools (tap drills) may slip during
work depending on the shape, type,
and surface condition.
In order to ensure safe and accurate
work, before starting work or during
work, check that the tip tool (tap drill)
is securely tightened with the keyless
drill chuck. Also, use a hexagonal
shaft type tip tool (tap drill) with high
holding force when you wish to
perform more accurate work.
• Tap mode is cancelled when no
operation is performed for about
5 minutes or immediately after the
battery pack is removed.
Tap mode settings
1. Press and hold the Speed setting
button/Tap mode button (L) for
2 seconds or longer.
The Tap mode lamp "FWD" lights up.
2. In Tap mode, press the Speed setting
button/Tap mode button (L) to change
the rotational speed.
The speed changes to L, H, M in this
order.
NOTE:
• To cancel Tap mode, press and hold
the Speed setting button/Tap mode
button (L) for 2 seconds or longer.
The Tap mode lamp turns off.
• During Tap mode, the rotational speed
is the same for motor voltage of both
18 V DC and 14.4 V DC
3 Mode LED Light
Press the light button to select illumination
setting.
Illuminated - Constant
Select by pressing lamp button light
will activate when trigger is pressed.
It will then stay illuminated for
approximately 5 minutes even if tool
is not used but will then switch off
automatically to save power.
Illuminated - On trigger
By pressing the lamp button again,
the mode will move to illumination
upon the pressing of the trigger
only.
Off
CAUTION:
Do not use it as a substitute for a
regular flashlight, since it does not have
enough brightness.
CAUTION: DO NOT STARE INTO
BEAM.
Use of controls or adjustments or perfor-
mance of procedures other than those
specified herein may result in hazardous
radiation exposure.
Battery Level Indicator
Press the battery level button.
NOTE:
The indicator will not show the battery
level when the button is pressed in the
following cases.
• The tool is powered off.
• Just after attaching the battery pack
• The main unit or battery level button is
not operated for approx. five minutes.
Press the battery level button again
after depressing the trigger switch.
- 13 -
EN