UNDERSTANDING ADVANCED DIAGNOSTICS
Advanced Diagnostics is used when displaying Error
Conditions. It will display a series of blink sequences
that help you identify the cause of the error and potential
solutions.
All Error Conditions are displayed with the Error LED
and Standby LED flashing back and forth. The number
of flashes between each pulse denotes a potential Er-
ror Condition (except reverse polarity and low-voltage
battery).
Error
Single
Battery will not hold a charge. Have
Flash
battery checked by a professional
Double
Possible battery short.
Flash
Have battery checked by a professional.
Battery voltage is too high for the
Triple
selected charge mode. Check the
Flash
battery and charge mode.
Error LED
Reverse polarity. Reverse the battery
Solid Red
connections.
Battery voltage is too low for charge
Standby
to detect or charger is in supply.
Solid
Jumpstart the battery to raise the
Orange
battery voltage.
Reason/Solution
Memory
Returns to last selected mode when restarted
Interactive
Alters the charging process based on organic
battery feedback
Recovery
Applies a high-voltage pulse charge when low-
voltage, sulfation or lost capacity is detected
Safe
Protects against reverse polarity, sparks,
overcharging, overcurrent, open-circuits,
short-circuits and overheating
Fast
Charges two times faster than traditional
battery chargers
Compensation
Adjusts for varying A/C line voltage for
consistent charging
Rugged
Dirt, water, UV, impact and crush resistant
Compact
High-frequency energy conversion for
ultra-compact, lightweight and portable charger
Start-Stop
Counteracts increased cyclic energy demands
placed on batteries in micro-hybrid vehicles
19