Installation And Connections - Genius GUARD 230V Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
P
o
w
r e
s
u
p
p
y l
A
b
s
o
b r
e
d
p
o
w
r e
S
e t
a
d
y
l
g i
t h
F
a l
s
h
n i
g
l
g i
t h
L
a
m
p
A
n
e t
n
n
a
O
p
r e
t a
n i
g
e t
m
p
e
a r
u t
e r
D
e
g
e r
e
f o
p
o r
e t
t c
o i
n
n I
s
l u
t a
o i
n
c
a l
s s
The GUARD flashing lamp was designed for installation in different positions, according to the installer's needs (Fig. 2).
N.B.:
- Securing the flashing lamp in both horizontal and upside-down position (Fig. 2 ref. D, E and F) is allowed only in protected places, e.g. in
underground garages. The flashing lamp cannot be secured in these positions if the application is located outdoors.
- To maintain the IP55 degree of protection, the flashing lamp must absolutely be installed on a flat surface. The flashing-lamp support must rest
in a uniform way.
As shown in Fig. 2, holes are provided on the flashing lamp support, for securing it in the different positions.
Flashing lamp installation procedure:
1- Select the installation position for the flashing lamp, respecting the following points:
a - the flashing lamp must always be installed vertically, with the exception of covered places, where it may be installed horizontally (Fig. 2).
b - the flashing lamp is a signalling device and, as such, it signals leaf movement. It must therefore be installed in a position where it can be
seen from all directions, and must not be unsighted by trees, signs or any other object.
c- the flashing lamp must be positioned close to the automated system.
N.B.: If points c and b cannot be adhered to simultaneously, we advise you to install two flashing lamps, one in a position visible from all
directions and the other close to the automated system.
2- If necessary, free, on the flashing lamp support, the securing holes for the selected position.
3- Secure the support in the desired position using expansion plugs size Ø5 ( Fig. 3).
4- Fig. 4 shows the cable routing zones. We advise you to separate the power cable from the antenna cable, to avoid bringing electrical noise
into the control unit. Positions "A" and "B" refer to two pre-drilled holes on the support, which, if used, must be opened.
5- Free a pre-drilled hole on the cap base and the wire sleeve holes too. The wire sleeve is designed for routing wires only - an entire cable cannot
be routed through it.
6- Position the wire sleeve in the freed hole.
7- Fit the cable in the flashing lamp support, according to the selected route, and then in the cap support as shown in Fig. 5.
8- Connect the cable to the terminals of the lamp-holder board, Fig.6.
9- Secure the lamp-holder to the cap base, exerting light pressure on the board until is anchored (Fig. 6).
10- Secure the cap base to the flashing lamp support, using the two supplied screws (Fig. 7).
11- Position the antenna support as in Fig. 8.
12- Cap installation procedure:
a- the cap can be oriented with the "GENIUS" logo in four different positions, every 90° (Fig. 9).
b- fit the cap with logo in the desired position, and gently turn it anti-clockwise until it is inserted into its seat.
c- turn clockwise until the cap is fully locked.
N.B.: A locking tab is provided on the cap base (Fig. 10 ref. A) - it must snap into the recess on the cap (Fig. 10 ref. B).
13- Fit the two front slides as shown in Fig. 11.
The GUARD flashing lamp is designed for installation of an antenna. Observe the following antenna installation procedure:
1 - Open the pre-drilled Ø 9 hole on the antenna support (Fig. 12 ref. A).
2 - Fit the antenna with the supplied accessories as shown in Fig. 12.
3 - Insert the cable in the flashing lamp (Fig. 12 rif.B).
4- Position the entire assembly on the flashing lamp support as in Fig. 13.
N.B.: Keep the power cables separate from the antenna cable, using separate sheaths for the cable route from the flashing lamp to the
control unit.
N.B.: The antenna support was designed for fitting ahead of the cap, which acts as an anti-extraction device.
The flashing lamp does not require scheduled maintenance.
Bulb replacement procedure:
1- Unscrew the locking system with a screwdriver as shown in Fig. 14, while turning the cap anti-clockwise.
2- Remove the cap and replace the bulb.
N.B.: For the correct type of bulb, consult the "specifications" table according to the installed flashing lamp model.
3- Re-fit the cap as described in paragraph 2 in point 12.
1. SPECIFICATIONS
G
U
A
R
D
2
3
0
V
~
2
3
0
V
~
+ (
6
%
1 -
0
%
)
4
0
W
N
O
Y
E
S
2
3
0
V
~
4
0
W
M
a
. x
E
2
7
1
O
P
I T
O
N
A
L
2 -
° 0
C
+
5
° 5
C
P I
5
5
C
a l
s s
I I

2. INSTALLATION AND CONNECTIONS

3. ANTENNA INSTALLATION (optional)
4. MAINTENANCE
M
O
D
L E
G
U
A
R
D
1
1
5
V
~
1
1
5
V
~
+ (
6
%
1 -
0
%
)
4
0
W
N
O
Y
E
S
1
5
V
~
4
0
W
M
a
. x
E
2
7
2
4
O
P
I T
O
N
A
L
2 -
° 0
C
+
5
° 5
C
P I
5
5
C
a l
s s
I I
G
U
A
R
D
2
4
V
D
C
2
4
V
d
c
1
5
W
Y
E
S
N
O
V
d
c
1
5
W
M
a
. x
E
1
4
1
2
V
d
O
P
I T
O
N
A
L
2 -
° 0
C
+
5
° 5
C
P I
5
5
C
a l
s s
I I
G
U
A
R
D
1
2
V
D
C
1
2
V
d
c
2
1
W
Y
E
S
N
O
c
2
1
W
M
a
. x
B
A
1
5
S
O
P
I T
O
N
A
L
2 -
° 0
C
+
5
° 5
C
P I
5
5
C
a l
s s
I I

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Guard 115vGuard 24vdcGuard 12vdc

Tabla de contenido