Assembly & Setup; Contents Of Carton; Tools Required - Troy-Bilt FLEX Serie Manual Del Operador

Ocultar thumbs Ver también para FLEX Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Assembly & Set-Up
Read entire Operator's Manual before
you attempt to assemble or operate
your new log splitter.
If you have any problems with the assembly of
your log splitter, please call (800) 828-5500. If
calling for assistance, please have the model and
serial number available.

Contents of Carton:

FLEX™ Log Splitter Attachment
Handle & Hardware
Operator's Manual
Fast Start Guide

Tools Required

Adjustable Wrench
Set-Up
WARNING: Use extreme caution
unpacking this machine. Some
components are very heavy and will
require additional people or
mechanical handling equipment.
Hydraulic Fluid
NOTE: The log splitter is shipped with hydraulic
fluid in the reservoir tank. You must check the fluid
level before operating. Proceed with the following
steps:
1.
Connect the FLEX™ Power Base to the
attachment on level ground. (See Controls &
Operation section under Connecting to the
FLEX™ Power Base.)
2.
Insert the handle into the slot on the handle
bracket. Make sure the handle is oriented
correctly. See Figure 3-1.
Figure 3-1
3.
Install the clevis pin and hairpin clip to the
handle. See Figure 3-2.
1
2
Figure 3-2
4.
Install the handle link. See Figure 3-3.
Figure 3-3
5.
Install the link plate to the handle link.
See Figure 3-4.
Figure 3-4
6.
Install link clip to the handle link.
See Figure 3-5.
Figure 3-5
7.
Remove the oil plug, which is located on the
end of the beam assembly. See Figure 3-6.
Figure 3-6
8.
Verify that the hydraulic fluid is to bottom of
fill plug. See Figure 3-6.
NOTE: Approved fluids include Shell
Tellus® S2 M 32 Hydraulic Fluid, Dexron® III/
Mercon® Automatic Transmission Fluid, Pro-
Select™ AW-32 Hydraulic Oil or 10WAW-ISO
Viscosity Grade 32 Hydraulic Oil. It is not
recommended that fluids be mixed. To top
off the reservoir tank during initial set-up,
use Shell Tellus® S2 M 32 Hydraulic Fluid
only, a funnel and keep the attachment on
level ground, so that you do not overfill.
9.
Replace and tighten the oil plug.
NOTE: The maximum fluid level will not be
achieved until the cylinder is cycled (See
the Controls Operation Section). Check the
level when the fluid is cold and with the log
splitter on a level surface. Never run below
this level, doing so will ruin the pump.
10.
Pull the locking pin (a) from the cylinder
base. Slide the cylinder back to lock in place.
See Figure 3-7.
Figure 3-7
3
5

Publicidad

Tabla de contenido
loading

Tabla de contenido