TROUBLESHOOTING
WATER LEVEL IN BOWL IS TOO LOW
A:
WATER FROM REFILL TUBE MUST
FLOW THROUGH OVERFLOW PIPE
Make sure the refill tube is supplying water down
overflow pipe. (Metal side out for refill clip)
B:
WATER LEVEL IN TANK MAY BE TOO LOW
1/2" below top of overflow pipe is recommended.
IF WATER LEVEL IS TOO LOW
Turn the tank water level adjustment
screw clockwise to raise the float.
Flush to reset water level.
IF WATER LEVEL IS TOO HIGH
Turn the water level adjustment screw
counterclockwise to lower the float.
Flush to reset water level.
+
Tank Water Level
Adjustment Screw
16
Refill Tube
Overflow
Pipe
1/2"
Overflow
Pipe
TROUBLESHOOTING
C:
FLAPPER MAY BE CLOSING TOO SOON
Give flapper chain approximately 1/2" of slack.
(small "j" shape)
For Kohler
toilets:
®
• If toilet isn't level and
leaning forward or
backward, losen or
tighten the back nut.
• If toilet isn't level and
leaning to the left or
right, losen or tighten
one of the two front nuts.