Descargar Imprimir esta página

Installation Instructions - eXtremeAir CPC9 El Manual Del Propietario

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions

WARNING:
WARNING:
WARNING:
Modifications including cutting holes may cause damage to the unit and will VOID the warranty.
WARNING:
WARNING:
1. Remove cover by removing (2) tamper‑proof screws using security wrench supplied. Pull cover directly toward you.
IMPORTANT: S
S
ave
2. Dryers should be placed at least 2 feet (61cm) apart and at least 12" (30cm) from washbasin. Do not install dryer
over washbasin. Dryers should be at least 18" (46cm) above any projection which may interfere with the operation
of the automatic sensor.
Hold the backplate to the wall at the suggested MAXIMUM mounting height. Measure from bottom edge of the
backplate to the floor (F
Maximum Mtg Height
MEN
44" (1118mm)
WOMEN
42" (1067mm)
CHILDREN
32‑42" (813‑1067mm)
DISABLED
36" (914mm)
3. Mark the locations of the four mounting holes and the conduit entrance location on the wall. (The conduit entrance
is the proper hole diameter for 1/2 inch (13mm) conduit.)
4. Fasten the backplate to the wall where previously marked. RECOMMENDATION:
Wood wall – No. 14 (M6) wood screws, 2‑3/4" (70mm) long
Cement or brick – 1/4" (M6) stud expansion bolts, 3" (76mm) long
Hollow wall – 1/4" (M6) toggle bolts, length depends on wall thickness
5. Run a single phase 120V or 230V 50/60Hz electrical service to the dryer location using either the in‑wall or bottom
surface 1/2"conduit entrance and connect to the lead wires as shown on the dryer schematic. The ground wire
must be connected to the dryer ground screw. IMPORTANT: All units must be supplied with 3 wire service.
Use No. 12 or 14 wire as required by local electrical rules. Unit must be installed with separate disconnect means
by a qualified licensed electrician.
CPC/GXT ‑ Connect each dryer to a dedicated 15 or 20 amp line.
EXT - Connect up to three dryers to one dedicated 20 amp line
Dryers located in shower rooms or other wet locations should be equipped with ground fault interrupter(s).
6. Adjusting Sound & Speed ‑ The dryer is shipped set at maximum speed. Using a small flat blade screwdriver,
CAREFULLY turn the SPEED pot COUNTERCLOCKWISE 3/4 TURN MAX. to REDUCE SOUND & SPEED.
CAREFULLY turn CLOCKWISE to INCREASE SOUND & SPEED. See Figure 2.
Disconnect Power Before Servicing
Installation Shall be Performed by a Qualified Licensed Electrician
Do NOT modify the product in ANY way
For Indoor Use Only
Cancer and Reproductive Harm – www.p65warnings.ca.gov
.
W
ecurity
rench
1).
igure
Mounting Diagram
5-5/8
(143mm)
9
16 " 15mm Max.
9
16 " 15mm Max.
3
8
16 " 208mm
Template is for all
American Dryer
EXTREMEAIR, ADVANTAGE
AND GLOBAL Series dryers
1
10
8 " 258mm Max.
Conduit Entrance
Outer perimeter
of ABS Cover
Revised 10/06/2014
Series Surface Mount
X
A
e
treme
ir
F
1
igure
Mounting Holes for
1/4" [M6] screws
15
8
16 " 228mm
3
9
8 " 238mm Max.
15
7
16 " 24mm
8 " 22mm
1
1
2 " 38mm

Publicidad

loading