Idiomas disponibles

display shows "SURE" (are you sure?) then pressing the SET button again, the display will
show "DELE" canceled and the LED will go from on to off thus completing the operation.
QUICK PROGRAMMING OF RADIO CONTROLS, t
r
eader
Quick programming of the Remote Controls, TAG Reader, Keyboard and/or NFC Reader is
allowed only when the receiver's entire memory is free. To make sure that the entire memory
is free, follow the Reset procedure.
Quick programming permits you to not select a new storage location every time for an ad-
ditional Device, but starting from position 0001 the control unit automatically increases the
storage location and remains in standby for 15 seconds from entering a new Device to be
stored. To exit the fast programming wait 15 seconds or press the SEL button.
OVERALL OPERATION TIME SLOT (TSTA ; TSTO)
With the receiver you can program a daily operation time slot for activation only at a
pre-set time.
Proceed as follows to choose the operation starting time: use the UP or DOWN button to
go to the TSTA storage position and press SEL and SET. Digits 1 and 2 will start flashing,
at the same time use the UP or DOWN button to select a number between 00 and 23 to
choose the operation starting hour and press SET to confirm (STOR will be displayed);
next, Digits 3 and 4 will start flashing, at the same time use the UP or DOWN button to
select a number between 00 and 59 to choose the minutes and press SET to confirm
(STOR will be displayed), thus completing the operation.
Proceed as follows to choose the operation ending time: use the UP or DOWN button to
go to the TSTO storage position and press SEL and SET. Digits 1 and 2 will start flashing,
at the same time use the UP or DOWN button to select a number between 00 and 23 to
choose the operation ending hour and press SET to confirm (STOR will be displayed);
next, Digits 3 and 4 will start flashing, at the same time use the UP or DOWN button
to select a number between 00 and 59 to choose the minutes and press SET to confirm
(STOR will be displayed), thus completing the operation.
NOTE: the Devices stored in the storage positions between 0950 and 0999 are not sub-
ject to the Time Slot function.
OVERALL ANTI PASS-BACK FUNCTION (BACK)
With the receiver you can select the Anti Pass-Back function (default = OFF), i.e. using
a couple of TAG Readers, Keyboards and/or NFC Readers (with different operation ad-
dresses set between them, Address 0 = input, Address 1 = exit ) once you have accessed,
you will need to exit the reserved area before accessing again. This operation can be
limited also for the Number of accesses or for its duration.
Proceed as follows to select the Anti Pass-Back function: use the UP or DOWN button
to go to the BACK storage position and press SEL and SET: all Digits will start flashing,
at the same time use the UP or DOWN button to select one of the following codes OFF
or ON-1, ON-2, press SET to confirm (STOR will be displayed); next, all Digits will start
flashing, at the same time use the UP or DOWN button to select a number between N000
r
, K
B
/
nFC
(N000 = all can access) and N949 for the maximum number allowed who can access the
ag
eader
ey
oard and
or
reserved area, then press SET to confirm (STOR will be displayed); next, all Digits will
start flashing, at the same time use the UP or DOWN button to select a time between
T000 minutes (000 = time excluded) and T999 minutes for the maximum time allowed for
remaining within the reserved area and press SET to confirm (STOR will be displayed),
thus completing the operation.
When selecting the Anti Pass-Back ON-1 function, you must always enter and exit from
the same access controlled by OUT 1 output.
Consequently the OUT 2 output can be used for connecting a traffic light (Red/Green)
indicator, for information on ramp momentarily busy or number of parking spaces still
available up to the limits set.
When selecting the Anti Pass-Back ON-2 function, you must always enter from the ac-
cess controlled by the OUT1 relay and always exit from the access controlled by the
OUT2 relay.
NOTE: The Anti Pass-Back function does not allow access via Remote Control.
NOTE: The Anti Pass-Back function is not allowed if the OUT1 Bistable mode was previ-
ously activated.
NOTE: The Anti Pass-Back function through the use of connected Keyboards foresees
that the devices have the ability to send the same serial code but with different addresses
set (one for input and the other for output), and at least a complete passage was carried
out during installation.
NOTE: the Devices stored in the storage positions between 0950 and 0999 are not sub-
ject to the Anti Pass-Back function.
RELAY OUTPUT OPERATION (OUT 1)
With the receiver you can select the Monostable or Bistable OUT1 relay output operating mode.
The Monostable operation (default), at each transit, activates the OUT1 relay for 1 second. With
the Bistable operation, a first transit activates the OUT1 relay, the next transit deactivates it.
Proceed as follows to select the desired operating mode: use the UP or DOWN button to go to the
OUT1 storage position and press SEL and SET: all Digits will start flashing, at the same time use
the UP or DOWN button to select one of the following codes MONO = Monostable or BIST=
Bistable, press SET to confirm (STOR will show on the display), thus completing the operation.
NOTE: at every OUT1 relay activation transit, the corresponding number stored will be
displayed for a few seconds.