METER knob setting
• Set Meter knob value at the position of "-", the smallest"field of view" will
be performed.
• Set Meter knob value at the position of "+", the largest"field of view" will
be performed.
• To adjust the Meter knob according to user's desire in between the position
of "+" & "-".
TIME knob setting
• Set Meter knob value at the position of "-", the smallest"field of view" will
be performed.
• Set Meter knob value at the position of "+", the largest "field of view" will
be performed.
• To adjust the Meter knob according to user's desire in between the position
of "+" & " ".
• Set TIME knob value at the position of "-", the minimum delay time will be
6sec.
• Set TIME knob value at the position of " + ", the maximum delay time will
be 12min.
• To adjust the TIME knob according to user's desire in between the position
of "+" & "-".
LUX knob setting
• Set LUX knob value at the position of " ", the minimum LUX value will be
5LUX. KDP8 has no reaction against the movement as the actual light level
is higher than 5LUX.
• Set LUX knob value at the position of "
performed, in such way KDP8 responds to the movement at any light level.
• To adjust LUX knob according to user's desire in between the position of "
" & "
".
Walk test
The purpose of the walk test is to select a proper installation place to get
the best detection range. Set the slide switch at the position of AUTO, turn
METER knob to "+", TIME knob to"-", LUX knob to " ", then conducting a walk
test referring to sectionTest procedure and LUX is disable (See FIG.18).