ommended that all necessary checks
be performed (appropriate program-
ming of the control panel and correct
installation of safety devices) to ensure
that compliant installation has been
performed.
- Fix the receiver to a wall, using the rele-
vant support which is fitted to the casing,
in such a way as to leave said support
facing downwards and insert the fixing
screws in the special holes.
- The receiver does not have any type of
isolating device for the 230 Vac line. It
is therefore the responsibility of the in-
staller to set up an isolating device inside
the system. It is necessary to install an
omnipolar switch, surge category III. It
must be positioned to provide protection
from accidental closing, pursuant to point
5.2.9 of EN 12453.
- For proper functioning of the radio re-
ceiver, if using one or more receivers, the
installation at a minimum distance of at
least 3 metres one from the other is rec-
ommended.
- Furthermore, care is required when drill-
ing holes in the outside casing where
connecting and power supply cables will
pass, and when assembling the cable
glands, so that everything is installed so
as to maintain the panel's IP protection
characteristics.
Radio Receivers
RES 2322 230V – RXH 2322 230V
comply with the specifications of the Directives:
RED 2014/53/EU, EMC 2014/30/EU, LVD 2014/35/EU.
The full text regarding the EU Declaration of Conformity is available from the following
Internet address:
http://www.seav.it
8