PLANNING FOR INSTALLATION
LOCATION PLANNING
The following should be considered when determining where to place your new
built-in side burner outdoor enclosure. It is best to identify the location of the side
burner prior to beginning any set up.
• Plan for easy access to the house considering weather conditions like
frequent rain or snow that would make it more convenient to have the side
burner located close to an entryway.
• Be sure to allow space for entertaining around the sides of the side burner as
it will become a gathering area during outdoor events.
• Ventilation is a key to the side burner's performance and smoke exhaust
should be considered when identifying a location.
• The side burner will smoke so consider the prevailing wind direction and
position the side burner so wind blows toward the front of the side burner to
move the smoke away and provide adequate airflow.
• Do not place the side burner under or near windows that may be opened to
your house as smoke will enter easily.
Ensuring proper Combustion Air and Cooling Airflow
•
Proper airflow MUST be maintained for the side burner to perform as it was
designed. If airflow is blocked, overheating and poor combustion will result.
Side burner INSTALLATION
W A R N I N G
FOR LP GAS CONVERSION:
• Conversion to LP gas must be performed by a certified gas technician.
• LP Conversion Kit Model must be used. Specific details for enclosure
construction are included in the conversion kit instructions.
• Additional enclosure venting construction is required.
NOTE: ENCLOSURE MUST BE CONSTRUCTED OF NON-COM-
BUSTIBLE MATERIALS.
BUILDING THE ENCLOSURE:
• NOTE: If this side burner is to be used as a replacement side burner in an
existing enclosure, consult your local contractor to determine if the side
burner will work correctly with your existing enclosure.
• Four "L" brackets are supplied for securing the side burner to the enclosure.
• If side burner enclosure design permits fastners only, four holes are provided
on bottom flange.
• Consult the table below for enclosure cut-out dimensions.
• The left rear corner of the enclosure must be open for gas connection
clearance. See Figures below.
NOTE: Area directly beneath the side burner must be open. No solid surface.
Side burner Model
Dim. A
463670619
17 1/4"
Side Burner
438mm
FRONT OF ENCLOSURE CUTOUT SHOWN
2.5" (63mm)
TOP OF ENCLOSURE CUTOUT SHOWN
BOTTOM OF SIDE BURNER SHOWN
P a ge 4
Dim. B
Dim. C
Dim. D
21 5/8"
11"
14 9/16"
548mm
279mm
370mm
1" minimum
Dim. A
Dim. E
Dim. D
C HA RB ROIL . CO M
Dim. E
15 13/16"
402mm