VDO Ocean Line 08 601 101 Instrucciones De Montaje
VDO Ocean Line 08 601 101 Instrucciones De Montaje

VDO Ocean Line 08 601 101 Instrucciones De Montaje

Cuentarrevoluciones electronico con cuentahoras de servicio
Ocultar thumbs Ver también para Ocean Line 08 601 101:

Publicidad

Enlaces rápidos

Installation Instructions

Publicidad

Tabla de contenido
loading

Resumen de contenidos para VDO Ocean Line 08 601 101

  • Página 1 Installation Instructions...
  • Página 2 Installation Instructions...
  • Página 3 Installation Instructions...
  • Página 4 Installation Instructions...
  • Página 5 Installation Instructions...
  • Página 6 Installation Instructions...
  • Página 7 Installation Instructions...
  • Página 8: Installation Instructions

    Installation Instructions / Generator Sender / Generator S / Generator C – http://sso-usa.siemensvdo.com/...
  • Página 9 Montage- und Bedienungsanleitung Installation and Operating Instructions Echolot Depth Sounder VDO Kienzle Vertrieb und Service GmbH 08 60103...
  • Página 10: Tabla De Contenido

    ....... 29 The VDO Depth Sounder......30 System components .
  • Página 11: Preface

    Manual should always be kept on board! Preface With the purchase of an instrument of the VDO marine program you sel- ected a high-quality product, made to the accepted State of the Art. Advanced production methods and the respect of the applicable quality assurance standards guarantee that our products are shipped in excel- lent condition.
  • Página 12: Safety Instructions

    Please note that all volatile electronic memories will lose their contents, and will have to be re-programmed if you disconnect the battery. The VDO instruments are not equipped with volatile memories. Risk of explosion! Run the engine compartment blower for a certain time before starting work in a gasoline engine compartment.
  • Página 13: For Maintenance

    SAFETY supply. The electrical outputs of the depth sounder indicating instrument and the connected cables must be protected against any direct contact or dama- Capacitors in the unit can retain their charge, even if the unit is separa- ted from its power supply. The cables must have a sufficient insulation resistance or voltage rating, and touching the contact points should be prevented.
  • Página 14: The Vdo Depth Sounder

    Analog scale Display Pushbutton The VDO depth sounder is an advanced depth measuring instrument designed for sport navigation. The pointer indicates the water depth below the keel in meters or feet on an analog scale when the system is active. This value is also shown as a digital value by the display in the lower dial section.
  • Página 15: System Components

    Accessories (not supplied with the system): Fixation parts kit (studs and bracket) N05 800 792 Illumination parts kit (24V /1.2W) N05 800 550 Repeater instrument VDO Depth Sounder N01 410 702 Alarm buzzer (12/24 V) N03 230 702 Spare parts:...
  • Página 16: The Functions Of The Vdo Depth Sounder

    The acoustical alarm can be muted by activating the pushbutton. Check the connection of the indicating instrument to the echo sounder first. Defective contacts may have caused the alarm. If the alarm continues, although the connection is perfect, please contact your VDO agency.
  • Página 17: Basic Calibration Of The Vdo Depth Sounder

    BASIC CALIBRATION Basic calibration of the VDO Depth Sounder Selection of the unit Setting the keel depth Keep the pushbutton pressed and switch the indicating instrument po- wer supply on. Wait until the display shows „UNIT“. Release the pushbutton. The current unit setting (feet in the example) is displayed.
  • Página 18: Setting And Activating The Shallow Water Alarm

    BASIC CALIBRATION / ALARM cally. The unit now displays the water depth below keel (4.6 m in the ex- ample). Setting and activating the shallow water alarm In unsafe depths and in waters with unknown depths the alarm will warn you in time to avoid shallows and to prevent boat damages.
  • Página 19 ALARM The acoustic alarm can be switched off by pressing the button. It stops automatically when the depth below keel is greater than the set thres- hold. The alarm function is deactivated if the button is quickly pushed twice when the current depth (2.7 m in the example) is displayed. Push button Push button...
  • Página 20: Troubleshooting

    TROUBLESHOOTING Troubleshooting Fault: Cause and correction: - No depth sounder function - Check electrical connections per wiring diagram. - Check supply voltage, 10.8 ... 32 VDC. - Check fuses in fuse box. - Wrong indication - Check display unit selection. - Check keel depth setting.
  • Página 21: Troubleshooting / Maintenance

    Even signs of the slightest wear require O-ring replacement. Order number: N05 801 418 O-ring for echo sounder / blind plug (2x). Installation of the VDO Depth Sounder system Please read the safety instructions on pages 28 and 29 prior to the installation.
  • Página 22 INSTALLATION Thread the indicating instrument cables from behind the mounting hole through the housing mounting nut. Place the supplied black rubber ring on the instrument back. Make the electrical connections of the indicating unit per cir- cuit schematically (see „Electrical installation“) and insert the instrument into the installation hole.
  • Página 23: Installation Of The Depth Sounder

    INSTALLATION Installation of the Depth Sounder The echo sounder unit must be installed in a turbulence-free zone in the hull. It should be mounted vertically. Do not install the sending unit close to external valves, anodes, log sending units, etc. to avoid influences by tur- bulence.
  • Página 24: For Internal Installation

    INSTALLATION Installation on powerboats: First Stringer Depth sending unit Installation of the echo sounder: internal installation An internal installation of the echo sounder is only possible on ships with a fiberglass reinforced hull. This does not apply to fiberglass sandwich hulls.
  • Página 25 INSTALLATION The echo sounder can be definitely fixed when you have found the opti- mum location. Install the echo sounder by bonding it with a salt-water resistant sealant. Install the echo sounder: Sealant Fixation by sealant: Avoid air bubbles between echo sounder and hull.
  • Página 26: For Through-Hull Installation

    INSTALLATION Installation of the echo sounder: through-hull installation Make a hole, 53 mm diameter, at the selected location. The hull thick- ness should not exceed 36 mm. Camber the hole out at 45 degrees for good sealant distribution and to obtain a reliable seal.
  • Página 27 INSTALLATION Insert the echo sounder into the hull sleeve and align the hole in the upper sounder section with the holes in the sleeve. Secure the sounder by inserting the retainer pin through the holes. Lock the retainer pin by installing the rings at both pin ends. Tie the control rope of the blind plug to one of the retainer pin rings.
  • Página 28: Electrical Installation

    INSTALLATION Electrical Installation System power supply Illumination...
  • Página 29: Connection Of A Repeater

    INSTALLATION Connection of a repeater Make the power supply con- nection for the repeater the same as the main unit (see page 44). The connection bet- ween the main and the repea- ter, including the alarm buzzer, is shown in the diagram below. Main-unit Repeater Note that the unit, keel depth...
  • Página 30: Circuit Diagram Legend

    INSTALLATION Advice on the connection of the alarm buzzer: If the alarm is triggered by the main-unit, the alarm buzzer will send a permanent sound. If the alarm is triggered by the repeater, the alarm buzzer will send an in- termittent sound.
  • Página 31: Technical Data

    DATA Technical data Measuring principle: Utrasonic running-time mesurement Application range: 0.5 to 120 m depending on ground and installation conditions Frequency: 200 kHz Supply voltage: 10.8 V ... 32 V DC Current consumption: Display unit: about 90 mA at 12 V DC without illumination, about 250 mA with illumination Echo sounder:about 50 mA at 12 V DC...
  • Página 32 Echolot Depth Sounder...
  • Página 33: Installation Instructions

    Installation Instructions MONTAGE- INSTRUCTIONS INSTRUCTIONES ANLEITUNG DE MONTAGE DE MONTAJE Rudder Angle Indicator Indicateur de position de gouvernail 08 601 104 Ruderlageanzeiger Indicador de position del timón Safety Instructions: Safety Instructions (electrical connection): Sicherheitshinweise: Sicherheitshinweise (elektrischer Anschluss): Technical details subject to change - Technische Änderungen vorbehalten - Sous réserve de modifications techniques - Quedan reservadas las modificaciones técnicas...
  • Página 34 Installation Instructions MONTAGE- INSTRUCTIONS INSTRUCTIONES ANLEITUNG DE MONTAGE DE MONTAJE Rudder Angle Indicator Indicateur de position de gouvernail 08 601 104 Ruderlageanzeiger Indicador de position del timón Consignes relatives à la sécurité Indicaciones de Seguridad Indicaciones de Seguridad (conexión eléctrica): Consignes relativesà...
  • Página 35 Installation Instructions MONTAGE- INSTRUCTIONS INSTRUCTIONES ANLEITUNG DE MONTAGE DE MONTAJE Rudder Angle Indicator Indicateur de position de gouvernail 08 601 104 Ruderlageanzeiger Indicador de position del timón 0.3 m plastic bezel chrome bezel Kunststoffring Chromring cerclage plastique cerclage chrome bisel plasico bisel cromado plastic bezel chrome bezel...
  • Página 36 Installation Instructions MONTAGE- INSTRUCTIONS INSTRUCTIONES ANLEITUNG DE MONTAGE DE MONTAJE Rudder Angle Indicator Indicateur de position de gouvernail 08 601 104 Ruderlageanzeiger Indicador de position del timón 12 V 12 V Technical details subject to change - Technische Änderungen vorbehalten - Sous réserve de modifications techniques - Quedan reservadas las modificaciones técnicas...
  • Página 37 Installation Instructions MONTAGE- INSTRUCTIONS INSTRUCTIONES ANLEITUNG DE MONTAGE DE MONTAJE Rudder Angle Indicator Indicateur de position de gouvernail 08 601 104 Ruderlageanzeiger Indicador de position del timón 24 V 24 V Technical details subject to change - Technische Änderungen vorbehalten - Sous réserve de modifications techniques - Quedan reservadas las modificaciones técnicas...
  • Página 38 Installation Instructions MONTAGE- INSTRUCTIONS INSTRUCTIONES ANLEITUNG DE MONTAGE DE MONTAJE Rudder Angle Indicator Indicateur de position de gouvernail 08 601 104 Ruderlageanzeiger Indicador de position del timón Technical details subject to change - Technische Änderungen vorbehalten - Sous réserve de modifications techniques - Quedan reservadas las modificaciones técnicas...
  • Página 39 Installation Instructions MONTAGE- INSTRUCTIONS INSTRUCTIONES ANLEITUNG DE MONTAGE DE MONTAJE Rudder Angle Indicator Indicateur de position de gouvernail 08 601 104 Ruderlageanzeiger Indicador de position del timón Technical details subject to change - Technische Änderungen vorbehalten - Sous réserve de modifications techniques - Quedan reservadas las modificaciones técnicas...
  • Página 40 Installation Instructions MONTAGE- INSTRUCTIONS INSTRUCTIONES ANLEITUNG DE MONTAGE DE MONTAJE Rudder Angle Indicator Indicateur de position de gouvernail 08 601 104 Ruderlageanzeiger Indicador de position del timón Only U.S.: For technical support, please visit us at our website: http://sso-usa.siemensvdo.com/ Technical details subject to change - Technische Änderungen vorbehalten - Sous réserve de modifications techniques - Quedan reservadas las modificaciones técnicas...
  • Página 41 Installation Instructions...
  • Página 42 Installation Instructions...
  • Página 43 Installation Instructions...
  • Página 44 Installation Instructions...
  • Página 45 Installation Instructions...
  • Página 46 Installation Instructions Ø Ø Ø Ø...
  • Página 47 Installation Instructions...
  • Página 48 Installation Instructions – http://sso-usa.siemensvdo.com/...

Tabla de contenido