Technical data
Measuring principle:
Application range:
Frequency:
Supply voltage:
Current consumption:
Transmitter power:
Operating temperature:
Type of protection:
EMC protection:
Dimensions:
DATA
Utrasonic running-time mesurement
0.5 to 120 m depending on ground
and installation conditions
200 kHz
10.8 V ... 32 V DC
Display unit:
without illumination, about 250 mA with
illumination
Echo sounder:about 50 mA at 12 V DC
about 40 Wrms, about 320 Wpp
-10 °C to +60 °C
DIN 40050 - IP 65 at front, IEC 529
CE: EN 50081-1, EN 50082-1
Indicating instrument:
Front ring diameter
Installation diameter
Installation depth
Installation depth
Sounder / Hull sleeve:
Installation diameter:
Maximum hull thickness:
For internal installation:
Maximum hull thickness:
Technical modifications reserved
about 90 mA at 12 V DC
105 mm
86 mm
56 mm (union nut)
90 mm (bracket)
53 mm
36 mm
12 mm
47