Descargar Imprimir esta página

Hog Slat Grow-Flex HS09 Especificaciones – Instrucciones De Operación E Instalación página 2

Reemplazo de sensor de alimento growerselect 230 vac con elemento de calentamiento

Publicidad

Idiomas disponibles

Idiomas disponibles

Grow-Flex
Feed System
TM
Wiring:
Installation in four (4) wire control systems:
Installation should be consistent with existing sensor wiring and OEM's recommendations. Use
the chart below to determine correct lead connection point for the HS09 per OEM's sensor
configuration. Note: The Hog Slat, HS09, leads should be connected to the same location as the
replaced OEM sensor's lead per this chart (Figure 2)
Lead
Normally Closed (NC)
Normally Open (NO)
Common
Note: Any wire(s) not used must be taped (insulated) for protection!
Adjustment:
The time delay and sensitivity can be adjusted with the small supplied screwdriver. Locate adjustment
potentiometers on the side of the sensor near the corded ended.
Delay range is 1 second to10 minutes. Clockwise to increase delay
Sensitivity range is 0-10/16 [15MM]. Clockwise to increase sensitivity
Operating Instructions:
All settings should be made with Product (Grain or Feed) not in contact with sensor (Sensor is not
Activated).
The HS09 has a time delay. The relay switches as soon as the sensor is activated (detects grain or
feed), but when the activation ceased, there is a delay before the relay switches back. The red LED
indicates the status of the sensor and the relay.
Steady Light-Sensor not activated
No Light-Sensor activated
Quick Flashing-Short time delay
Slow Flashing-Long time delay
Hog Slat Inc. Newton Grove, NC USA May 2018
Hog Slat
HS09
Black 3
Black 4
Black 1
L2
Blue
L1
Brown
CTB
AP
34255
1002
Black 3
Red
Black 4
Orange
Black 1
Green
Blue
Black
Brown
Brown
Figure 2
Figure 3
Normally not used
2

Publicidad

loading