HeatLink 11600 Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Instruction Manual
11600
2" Press Instructions; 2 Position Auto Press
Never press with empty jaws as this will damage the jaws.
Regularly check tool jaws and sleeve for any abnormalities that could be an indication of a damaged tool.
Never re-use stainless steel press sleeves.
1. Open the jaws (squeeze at the points indicated in the diagram)
and position squarely around the sleeve, then allow the jaws to
firmly grasp the sleeve.
2. Squeeze the trigger until the press is complete.
Note: if the red LED flashes or there an audible beep, consult
"Tab. 1."
2"
3. Open the jaws and reposition them 90° from the first press.
Second Position
Example Presses
"
1
3
2
1
"
1
1
1
4
HE.16527_D © 08/2015
First Position
®
Heat
Link
®
Heat
Link
90°
"
1"
4
"
2"
2
4. Squeeze the trigger until the second press is complete.
5. Open the jaws and remove the tool from the sleeve.
6. Inspect the connection to ensure the tubing is still properly
seated (only PEX is visible in sleeve sight hole), and the press
has been properly formed onto the sleeve (see diagram for
guideline).
Tool jaws imprint "HL" on the sleeve.
An improperly positioned tool may result in a poor press and a
damaged fitting.
Sight
Hole
Pinched Stainless Steel Sleeves
If the stainless steel sleeves are being pinched, the tool jaws are
worn out or damaged and must be replaced.
Improperly
positioned
jaws
PEX
improperly
seated in
sleeve
V