1.0
VISTA GENERAL ........................................................................ S-1
1.1
Entrepaño del Despliegue/la Definicion de Botones ... S-1
2.0
PREPARACION PARA EL USO ................................................... S-3
2.1
Poder .................................................................................... S-3
2.2
De Entrada / Las Conexiones de salida ....................... S-4
3.0
MENU ......................................................................................... S-5
4.0
OPERACION ............................................................................... S-6
4.1
Modo Interno -
La Operacion Estroboscopica Uniforme ....
4.2
Modo Interno -
El Generaor de la Frecuencia de TACH .....
4.3
Modo De Entrada Externo .............................................. S-10
4.4
Modo del Tacometro -
4.5
Modos Externos de la Demora (Fase que Cambia) ... S-11
4.6
Poder Arriba Caracteristicas ....................................... S-12
5.0
UTILIZAR EL ESTROBOSCOPIO PARA MEDIR RPM ............... S-13
6.0
LIMITACIONES DE SENSORES OPTICOS REMOTOS .............. S-15
7.0
El REEMPLAZO de LAMPARA Y FUNDE ................................. S-16
7.1
Reemplazo de lámpara .................................................. S-16
7.2
Funda .................................................................................. S-18
8.0
LA BATERIA ACCIONO LOS MODELOS SOLO ....................... S-18
8.1
Indicación baja de Batería ............................................. S-19
8.2
Cargar las Baterías ......................................................... S-19
8.3
Alimentación Corcel Externo ........................................ S-20
8.4
Disposición de Batería ................................................... S-20
9.0
ESPECIFICACIONES ................................................................ S-21
10.0 OPCIONES Y ACCESORIOS ..................................................... S-23
La Entrada Externa Requirio .......
Memory
Output Pulse
Input Power
Light Output
Flash Duration
Flash Tube (Lamp) Life 100 million flashes
S-7
Run Time
S-10
Charge Time
S-11
Weight
This product is designed to be safe for indoor use under the following
conditions (per IEC61010-1).
Operating Temperature 32-104 ºF [0-40 °C]
NOTE: Safety thermal feature will set unit into TACH Mode (stops
flashing) in the event of internal overheating.
Humidity
Last setting before power down is remembered
and restored on next power up. 9 user settable
flash rates.
40 µsec positive/negative pulse (menu
selectable), 3.3 Vdc typical
Internal Rechargeable Batteries 6 Vdc, External
AC recharger (115 Vac to 230 Vac)
Average: 13 Watts typical > 4000 FPM
Instantaneous (per flash): 230 mJoule typical
to 4000 FPM
10-25 microseconds (auto adjust with flash rate)
2 hours typical at 1800 FPM, and over 1 hour at
6000 FPM with fully charged batteries
4-5 hours typical with PSC-pbxU
1.875 lbs [0.8505 kg] including batteries
Maximum relative humidity 80% for temperature
up to 88 °F [31 °C] decreasing linearly to 50%
relative humidity at 104 °F [40 °C]