Publicidad

Enlaces rápidos

1.800.544.2843
MONARCH INSTRUMENT
Pocket Laser Tach 200
Tachometer / Rate Meter / Totalizer / Timer
www.calcert.com
15
10
20
5
25
0
30
Instruction Manual
(PLT200)
sales@calcert.com

Publicidad

Tabla de contenido
loading

Resumen de contenidos para MONARCH INSTRUMENT PLT200

  • Página 1 MONARCH INSTRUMENT Instruction Manual Pocket Laser Tach 200 (PLT200) Tachometer / Rate Meter / Totalizer / Timer 1.800.544.2843 www.calcert.com sales@calcert.com...
  • Página 2: Laser Radiation

    SAFEGUARDS AND PRECAUTIONS LASER RADIATION AVOID DIRECT EYE EXPOSURE CLASS 2 LASER PRODUCT MAX OUTPUT POWER: 1mW EMITTED WAVELENGTH: 650nm CLASSIFIED TO IEC 60825-1:2001 WARNING - This product emits a visible beam of laser light. Avoid exposure to the laser radiation. The use of optical viewing aids (binoculars, for example) may increase the ocular hazard.
  • Página 3: Tabla De Contenido

    TABLE OF CONTENTS 1.0 OVERVIEW ................E-1 2.0 FEATURE LOCATIONS ............E-1 3.0 LCD DISPLAY SYMBOLS ............ E-2 4.0 PLT200 SPECIFICATIONS ........... E-3 5.0 INPUT / OUTPUT ..............E-7 6.0 PREPARATION FOR MEASUREMENT ......... E-8 6.1 Non-Contact Preparation .......... E-8 6.2 Direct Contact Preparation ........
  • Página 4: Overview

    Totalizer and Timer. It is programmable to read in English or Metric units. An input socket accepts remote sensing devices and an output socket allows for pulse output to external indicating devices. The PLT200 can be tripod mounted and “Locked-On” for accurate and continuous operation. This tachometer also stores minimum, maximum and last measurement in memory.
  • Página 5: Lcd Display Symbols

    3.0 LCD DISPLAY SYMBOLS On Target Indicator. Blinks on whenever there is an input signal. Will appear to be solid on at higher frequencies. Low Battery icon. Indicates that the batteries are low and need to be replaced. Times Ten icon. Indicates that the value shown is ten times that which is displayed.
  • Página 6: Plt200 Specifications

    4.0 PLT200 SPECIFICATIONS Laser Specifications: Classification: Class 2 (per IEC 60825-1 Ed 1.2 2001-8) Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001. Maximum Laser Output: 1mW Pulse Duration:...
  • Página 7 Contact Specifications (continued): Accuracy: Revs: ±0.05% of reading (RPM) or resolution limit (with no slippage) ±0.5% of reading or resolution limit (with no Linear: slippage) Contact Measurements Ranges: TACHOMETER: Revolutions per Minute (RPM) 0.5 to 20,000 RPM Revolutions per Second (RPS) 0.0833 to 333.33 RPS Revolution per Hour (RPH) 30 to 999,990 RPH...
  • Página 8 Contact Measurements Ranges (continued): RATES: Wheel Circumference: Yards per Hour 10cm: 3.281 to 131,233 YPH 12 in: 10.000 to 240,000 YPH Miles per Hour 10 cm: 0.002 to 74.564 MPH 12 in: 0.006 to 136.36 MPH Centimeters per Second 10 cm: 0.084 to 3,333.3 CM/S 12 in: 0.21 to 3,048.0 CM/S...
  • Página 9 Display: Dual LCD Display (5-digit upper/scrolling, 5-digit alphanumeric lower display) Batteries: 2 “AA” 1.5 V (DC) alkaline included (Note: Batteries are NOT rechargeable.) Battery Life: 30 hours continuous typical with batteries provided External Input: Absolute max: -0.3 V to 5 V (DC) Minimum: low below 1.2 V and high above 2 V (TTL compatible)
  • Página 10: Input / Output

    5.0 INPUT / OUTPUT Input: Accepts remote sensor or Remote Contact Assembly (RCA). 1/8” (3.5mm) stereo phone plug. Output: 1 pulse per revolution TTL output on internal operation. Pulse repeater with external sensors. 1/8” (3.5mm) mono phone plug. Input socket ( Output socket ( Common Signal Input...
  • Página 11: Preparation For Measurement

    6.0 PREPARATION FOR MEASUREMENT 6.1 Non-Contact Preparation For Internal operation (Red laser) or External operation using optional Remote Optical Sensor (ROS-Red LED). 1. Clean 2. Apply 1/2” Shaft square T-5 Reflective tape For Small Shafts: As small as 1/8” wide on side or radius edge 6.2 Direct Contact Preparation For External operation ONLY using optional Remote...
  • Página 12: Connecting External Sensors

    2. 10 cm Wheel 3. 12 inch Wheel Install with pin in shaft fully seated Tighten screw in slot. securely into flat Tighten on shaft. screw. 6.3 Connecting External Sensors Plug sensor into Input socket Remote Contact Assembly (RCA) (shown with optional 12 inch wheel) Remote Optical Infrared Sensor Magnetic Sensor...
  • Página 13: Taking Measurements

    Linear (Use concave tip for small shafts) to RCA from PLT200 from PLT200 ONLY USE MODERATE PRESSURE WARNING: Making measurements in direct contact with rotating equipment can be dangerous. Keep all loose clothing and hair away from exposed moving machinery. Keep the hand holding the instrument well behind the back end of the Remote Contact Assembly.
  • Página 14: Tachometer Mode

    8.0 TACHometer Mode Tachometer measures speed or linear rate with respect to time. Time intervals are seconds, minutes, or hours. Rotational speed can be measured in Revolutions (Revs) per second, per minute, or per hour. The most common measurement is RPM or Revs per minute using the optical tachometer mode.
  • Página 15 Enter selection RPS, RPM or RPH of Units Select Units Repeat until desired Units displayed Save and advance Enter selection NONE, 1, 2 or 3 of number of decimal places 10. Select decimal Repeat until places desired decimal places displayed 11.
  • Página 16: Tachometer Operation

    8.2 TACHometer Operation Measure Press and hold Lock on Recall Max Max Speed Recall Min Min Speed Resets Max/Min If unit Locked Power OFF Automatic after 90 seconds if unit not Locked on 9.0 RATE Mode Measurement of units in addition to Revs requires the attachment of the Remote Contact Assembly and tips/wheels.
  • Página 17: Rate Setup

    9.1 RATE Setup Turn EXTRN, then scrolling Power message, then last Units selected 1a. To toggle Lock On/Off Press and Hold Locked On Enter Setup Enter Last Mode selected is selection displayed of Mode Select Toggles between RATE RATE and TOTAL. Mode Select RATE.
  • Página 18 RATE Setup (continued): Select Units Repeat until desired Units displayed Save and advance Rotational Units Linear Units Only for Linear Units: 8a. Enter Last Wheel selection of selected is Wheel displayed 8b. Select Toggles Wheel between 10CM and 12IN 8c. Save and Advance Enter selection NONE, 1, 2 or 3...
  • Página 19: Rate Operation

    12. Exit Setup – DONE, Ready to USE CONTACT TIP or measure [wheel selected], then Units selected Unit will remember these settings (including lock on/off) even if turned off and back on. 9.2 RATE Operation Measure Press and hold Lock on Recall Max Max Speed Recall Min...
  • Página 20 Despliegue: 5 x 0.5” (12.7mm) dígitos numéricos más 5 alfanuméricos LCD Baterías: 2 “AA” 1.5 V (CC) alcalinos incluidas (Notese: Baterías NO se pueden volver a cargar.) Vida de Batería: típicamentes 30 horas continuas con las baterías suministrados Entada externa: Máximo absoluto: -0.3 V a 5 V (CC) Mínimo:...
  • Página 21 Save and advance Enter Different options displayed for selection of Internal or External operation. Units Internal or External ROS: External Remote Contact Assembly: Rotational: REV COUNT Only Linear: INCH, FEET, YARDS, CM, METER Select Units Repeat until desired Units displayed Save and advance COUNT or REV...
  • Página 22: Totalizer Setup

    TOTALizer Setup (continued): Enter selection NONE, 1, 2 or 3 of number of decimal places 10. Select decimal Repeat until places desired decimal places displayed 11. Save and advance 12. Exit Setup – Ready to measure Units = COUNT: Rotational/Linear Units: DONE, DONE, then COUNT...
  • Página 23: Totalizer Operation

    10.2 TOTALizer Operation Measure Press and hold Lock on Recall Max or Max or Min Speed (in last selected Tach or Rate mode units) Recall Time Shows time in seconds in seconds from when the Start / Reset button is pressed until the last input signal measured.
  • Página 24: Timer Mode

    11.0 TIMER Mode Accumulates time in minutes, seconds, and tenths of a second. There are two modes of operation. The Manual mode operates like a stopwatch, the timing period being started and stopped by the user. The Auto mode can be stopped and started by the user or a piece of reflective tape on objects.
  • Página 25: Timer Operation

    Enter selection MAN or AUTO of Timer function Select Timer Toggles between Manual and function Auto Save and advance Exit Setup – DONE, then Units Ready to selected measure Unit will remember these settings (including lock on/off) even if turned off and back on.
  • Página 26: Batteries

    TIMER Operation (continued): With Timer running - Stops at elapsed time to date. To continue, press again. If Timer stopped - Power Off Automatic after 90 seconds (if unit not Locked on) Automatic after 99:59.9 12.0 BATTERIES When displayed, replace batteries. Remove battery cover Install two 1.5V...
  • Página 27: Cleaning

    13.0 CLEANING To clean the instrument, wipe with a damp cloth using mild soapy solution. 14.0 OPTIONS /ACCESSORIES Reflective Tape, 5 foot [1.5 m] roll, ½ inch [13 mm] wide Remote Contact Assembly with 10 cm wheel, concave and convex tips Concave/convex contact tips and 10 cm linear contact wheel 12 inch Wheel...