Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to
avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation
Read these instructions carefully so as to familiarise yourself with the appliance before fiting the appliance to a gas cylinder.
1. General
• This appliance complies with BS EN498:2012 and SANS 1539:2012
• This appliance may only be used with an approved hose and regulator (A 2.8kPa hose and regulator supplied with this unit in South
Africa)
• The gas cylinder is to be used in the upright position.
• Only to be used with a gas cylinder that does not exceed 500mm in height(Regulator is included) and 400 mm in width.
• Gas appliances require ventilation for efficient performance and to ensure the safety of users and other persons in close proximity.
• Warning: Accessible parts may be very hot. Keep young children away.
• After use, turn off the gas supply at the cylinder, and then at the control knobs.
• When using a pot, the minimum recommended pot size is 150mm and maximum recommended size is 300mm.
• Use outdoors only!
Country of use
Appliance Catagories
Allowable gases and
operating pressure
Jet number
Nominal usuage
Gross nom. heat input
Jet number
Nominal usuage
Gross nom. heat input
Jet number
Nominal usuage
Gross nom. heat input
a)
A refillable gas container not exceeding 11kg and complying with local regulation in force.
1) For gas categories I3B/P(30)
Meridian 3B with side tables, models 98522, total nominal heat input 9.6kW @ 699g/h.
Meridian 4B with side tables, models 98533, total nominal heat input 12.4kW @ 904g/h.
Meridian 3B with side table & side burner, models 98510, total nominal heat input 12.5kW @ 910g/h.
Meridian 4B with side table & side burner, models 98512 total nominal heat input 15.3kW @ 1115g/h.
2) For gas categories I3B/P(37)
Meridian 3B with side tables, models 98250-31, total nominal heat input 11.4kW @ 828g/h.
Meridian 4B with side tables, models 98251-41, total nominal heat input 15.2kW @ 1104g/h.
Meridian 3B with side table & side burner, models 98250-33, total nominal heat input 14.5kW @ 1054g/h.
Meridian 4B with side table & side burner, models 98251-43 total nominal heat input 18.3kW @ 1330g/h.
CAUTION
must be provided.
IMPORTANT
Retain these instructions for future reference.
DK, FI, NO, NL, SE,
BE, ES, FR, IE, IT, PT,
AT, SI
I3B/P (30)
I3+ (28-30/37)
Butane @ 28-30mBar
Butane @ 28-30mBar
Propane @ 28-30mBar
Propane @ 37mBar
Butane/Propane mixtures
@ 28-30mBar
(SA - LPG @ 2,8kPa)
Main 3 Burner BBQ unit
(98510, 98522)
Butane - 233 g/h
Butane - 233 g/h
per burner
3.2 kW per burner
3.2 kW per burner
(9.6 kW in total)
(9.6 kW in total)
Main 4 Burner BBQ unit
(98512, 98533)
Butane - 226 g/h
Butane - 226 g/h
per burner
3.1 kW per burner
3.1 kW per burner
(12.4 kW in total)
(12.4 kW in total)
Side Burner (98510, 98512)
Butane - 211 g/h
Butane - 211 g/h
2.9 kW
Gas supply sources:
1 1
PL
GB, CH
I3B/P (37)
Butane @ 37mBar
Propane @ 37mBar
Butane/Propane mixtures
@ 37mBar
0.92
Butane - 276 g/h
per burner
per burner
3.8 kW per burner
(11.4 kW in total)
0.92
Butane - 276 g/h
per burner
per burner
3.8 kW per burner
(15.2 kW in total)
0.84
Butane - 226 g/h
2.9 kW
3.1 kW