SPECIFICATIONS
Range . . . . . . . . . . Up to 30 ft. (9.1 m)
Sensing Angle . . . . Up to 180°
Electrical Load . . . . See rating on fixture for
Sensor Capacity . . Up to 360 Watt (3.0
Power
Requirements . . . . 120 VAC, 60 Hz
Operating Modes . . T E S T, AU TO, a n d
Time Delay . . . . . . 1, 5, 10 minutes
D
B
timer . . Off, 3, 6 hrs, Dusk-to-
®
ual
rite
HeathCo LLC reserves the right to discontinue
products and to change specifications at any
time without incurring any obligation to incorpo-
rate new features in products previously sold.
SYMPTOM
POSSIBLE CAUSE
Light will not
1. Light switch is turned off.
come on.
2. Bulb is loose or burned out.
3. Fuse is blown or circuit breaker
4. Daylight turn-off is in effect
5. Incorrect circuit wiring, if this is
Light comes on
1. Light control may be installed
in daylight.
2. Light control is in Test. (Set
200477-02
[varies with surrounding
temperature].
maximum wattage.
A.) Maximum Tungsten
Incandescent
MANUAL MODE
Dawn
TROUBLESHOOTING GUIDE
is turned off.
(recheck after dark).
a new installation.
in a relatively dark location.
control switch to an ON-TIME
position.)
SYMPTOM
POSSIBLE CAUSE
Light comes
1. Light control may be sensing
on for no ap-
parent reason.
Light stays on
1. The sensor is pointed toward
continuously.
2. Light control is in Manual Mode.
3. Light control is in D
4. Sensitivity is set too high. (Re-
Light flashes
1. Light control is in the Test
on and off.
7
small animals or automobile
traffic (Reduce sensitivity).
a heat source like an air vent,
dryer vent, or brightly-painted
heat-reflective surface.(Reduce
sensitivity.)
(Switch to Auto.)
ual
mode.
duce sensitivity.)
m o d e a n d wa r m i n g u p.
(Flashing is normal under these
conditions).
B
®
rite