JABSCO ITT 52700 Guia De Instalacion página 3

Tabla de contenido

Publicidad

Mounting:
Horizontal
Mounting
Installation:
1: Remove shipping plugs from the pump ports.
2: Connect hose to snap
fittings provided (A) and
strainer (B). Use 3/4"
(19 mm) braided reinforced
hose and a worm clamp
for hose connection to all
fittings.
3: Fasten pump to a flat
surface using grommets
provided. Do not over
tighten screws to allow grommets to absorb
vibration.
4: Insert Pumpgard
(C). Insert outlet fitting to pump outlet. Snap the
clip closed to retain the strainer and fitting firmly in
the pump body.
WARNING – SAFETY PRECAUTION
Electrical:
Failure to follow the procedures below will void the
product warranty and/or cause possible harm to
persons or pump. In accordance with ABYC E-11,
AC and DC Electrical Systems on Boats guidelines.
Please reference Illustration A on fold out panel for
wiring instructions.
Operation:
1: Open seacock.
2: Open hose bib and/or pressure nozzle.
3: Turn on pump.
4: Close pressure nozzle/hose bib when water
runs free of air. Pump is now ready for automatic
demand operation.
5: For prolonged operation, pump must operate at
full open flow or motor will overheat.
NOTE: Do not operate longer than 15 min.
continuously!
Vertical
Mounting
strainer into pump intake port
TM
This is a high pressure pump. Prior
to activation, ensure that the hose
clamps, discharge hose and snap
fittings are secure. The pump
must be properly anchored to a
solid surface.
Do Not Submerge
in Bilge Water
(A)
(C)
(B)

Publicidad

Tabla de contenido
loading