Utilization; Diagram Of Viper P10 Press Fitting Machine; Listing; Choice And Positioning Of Jaws - Virax Viper P10 Manual De Utilización

Máquina de prensar manual hidráulica
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24

Utilization

Diagram of Viper P10 press fitting machine

6

Listing

Choice and positioning of jaws

The section "Jaws and profiles" on p44 shows the various jaws available on the market. Refer to
this section to select the jaws suited to the work to be undertaken.
How to fix the jaws on the press
Fixing the jaws is a simple and rapid operation.
Observation:
Before operating the press, put the pad-rollers (4) in the rear position. To do so, press on the
return trigger (5) until the rollers have returned to their rear position.
Unlock the locking spindle:
Rotate the wheel (2) to align the notch of the latter with the screw (3). The spring of the
locking spindle extends.
Observation:
The locking spindle is kept locked using a locking screw which slides in the groove of the wheel.
Slide the jaws in the head of the press.
Observation:
The pad-rollers must be in the rear position to allow the jaws to be positioned satisfactorily.
5
Name of part
1
Press head
2
Locking spindle wheel
3
Locking screw
4
Locking screw
5
Pad-rollers
6
Return trigger
7
Pumping handle
2
1
4
3
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

2530 10

Tabla de contenido