Cleaning And Care - HoMedics mychill PERSONAL SPACE COOLER 2.0 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
REPLACING THE COOLING CARTRIDGES
Replace the Cooling Cartridge seasonally or after 540 hours of use for optimal performance. The MyChill Personal Space Cooler is equipped
with a Replace Cooling Cartridge LED that illuminates Red after 540 hours of use indicating the cooling cartridge needs to be replaced.
To purchase genuine HoMedics replacement cooling cartridge, Model PP-PAC25FLTR, go to your retailer where you purchased your
MyChill Personal Space Cooler, or visit www.homedics.co.uk.
NOTE: If you live in an area with hard water, it may need to be replaced more frequently. In these instances, you will notice mineral
build-up on the cooling cartridge that over time may restrict air flow.
1. Unplug the Power
Adaptor from the wall and
from the unit. Remove the
water tank from the top
housing.
5. Replace the Top Cover
onto the water reservoir.

CLEANING AND CARE

CAUTION: Before cleaning the unit, turn power off and unplug the
power adapter from the wall and the unit.
1. To Clean the Tank and Reservoir
Remove the water tank from the personal space cooler by lifting
it from the main unit. Unscrew the tank cap and rinse inside the
tank with clean water. Empty, rinse and dry the tank, tank cap and
water reservoir before refilling. To remove any scale or build up,
use a 50/50 mixture of white vinegar and lukewarm water to clean
the inside of the tank and reservoir as needed
2. To Clean the Cooling Cartridge
Rinse with clean water
3. To Clean the Pump Filter
Check and clean the pump filter as needed. Remove the pump
filter, brush clean with a soft bristle brush (not included) and rinse
clean. Dry and re-install.
NOTE: Never run water over the pump filter while it is installed.
4. To Clean the Surface
Clean the surface of the unit with a clean damp soft cloth as often
as needed. Never use detergents, excess water, treated cloths,
harsh cleaning agents or sprays.
2. Press the release
buttons on both sides and
slowly lift the top cover,
allowing time for the water
to drain.
6. Refill the Water Tank and
Reservoir as described in the
"How to Fill" section.
6
I
3. Pour out any excess
water remaining in the
Water Reservoir, then
remove the old Cooling
Cartridge and discard.
7. Plug the Power Adaptor
into the back of the unit
and the other end into a
household electrical outlet to
resume operation.
1.
3.
Storing your personal space cooler: Clean the Tank and Water
Reservoir with a 50/50 mixture of white vinegar and water. Wipe
the underside of the Top Cover with a soft, damp, cloth. Rinse the
Cooling Cartridge with water and allow to air dry. Be sure to rinse
thoroughly and let all parts dry completely before packing in the
original carton and store in a cool, dry location.
GB
4. Set the new Cooling
Cartridge in place. Be sure
the Cooling Cartridge
is positioned with the
"V-shaped" vents upward.
8. Turn the unit on, then
press and hold the Cooling
Cartridge Reset Button for 5
seconds. The LED will flash to
indicate the Replace Cooling
Cartridge Timer has been reset.
2.
4.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mychill pac-25-eu2

Tabla de contenido