Day/Night Mode:
The thermostat will switch between Day and Night mode depending on
the time and use the corresponding temperature settings. F06 is setting
for daytime and F07 for night. F06 must be smaller than F07.
Heating/Cooling
With F05 the device can be switched between Heating and Cooling Mode!
There is a 3 minute delay when changing this setting to avoid damaging
compressors.
In Heating mode the device will be operated until the desired temperatu-
re is reached. In Cooling mode the device will be switched on as soon as
the temperature is above the setting and only switched off if the tempe-
rature decreases below the setting again. Use this mode for fans.
Alarm Function:
You can set an alarm function, which will warn you if a certain deviation
from the temperature setting is reached. The deviation can be set from
0 to 15. Choosing 0 will shut off the alarm function. If the deviation is
set to 5 and the desired temperature is 25°C, the alarm will start at
30°C and below 20°C. In case of alarm there is a warning sound and the
display flashes.
Timer:
The device has a real-time clock with timer. You can set two ON and two
OFF times (in minutes) which will allow controlling devices, e.g. lighting
plugged into coupling II by time. Set the respective menus (F08 to F11)
to the desired time or to 00:00 if you do not want to use the timer. Make
sure that the settings are not contradictory, e.g. the setting for F10 must
not lie between F08 and F09.
Mode of Operation:
The thermostat turns the heating on until the temperature setting is
reached and then turns it off. It will turn on again if the measured tem-
perature is below the difference of the temperature setting and value
set at F03.
Display and Showing the settings:
If a red lamp is lighting above WORK the device is on. If a lamp is lighting
above SET the device is in settings mode.
With the arrow key up you can display the daytime temperature setting.
Down key will show the nighttime setting. ENT will show the actual time.
All other settings can only be viewed in settings mode.
Important Information:
• If the temperature range (0°-50° C) is exceeded the display will show
HHH for a higher and LLL for a lower temperature and an alarm will
sound.
• In case of sensor error an alarm will sound and the display will show
EEE. Contact your dealer.
• The device saves settings in case of power loss for about 48 hours.
• Do not undertake any modification and do not open the case.
• Device and sensor cords have to be checked always for signs of dama-
ge. If a defect is discovered the device has to be put out of operation
immediately. The same applies if the device has come into contact with
fluids.
• Generally it should be verified if the device is applicable for the appli-
cation at hand before putting it into operation!
• In case of doubt consultation of experts or the manufacturer of the
employed devices is required.
• In order to avoid animal losses regular checks of the temperature are
required. Claims for losses due to malfunction of the controller cannot
be accepted.
• Do not use light bulbs (incandescent spot lamps) with a thermostat.
Since the thermostat often turns the lamps on and off, their live time is
significantly reduced and it causes a lot of stress for the animals.
Warranty
The warranty expires in case of modification and repair attempts as well
as damaging by force or inappropriate usage.
A manufacturer warranty of 2 years is granted on this device. Repair,
amendments or exchange for a replacement are at the manufacturer's
discretion.
Neither a guarantee nor any liabilities for detriments or consequential
damages in relation with this product will be assumed.
In case of warranty claims or repairs contact your specialist dealer.
Technical Specifications
Voltage:
Maximum Load:
Power Consumption:
Temperature Setting:
Temperature Range:
Accuracy:
Resolution:
Temp. Difference for Switching:
Alarm when exceeding temp:
230 V~ 50/60 Hz
1000W
< 1,5W
0° to 50°C
0° to 50°C
+- 1°C
0,1°
0-15°C
+- 0° to 15°C
5