VIKING RANGE CORPORATION
INSTALL ELECTRICAL WIRING
Interior Blower Installation
CAUTION: All electrical wiring should be done
!
by a qualified person(s) in accordance with all
applicable codes and standards.
1. Mount a standard wiring box, with 3-pronged receptacle, inside
the cabinet. Make sure the downdraft's power cord can easily
reach it.
2. Run appropriate power cable into cabinet and connect it to
receptacle.
3. Plug the downdraft's power cord into the outlet. Make sure that
the power cord is routed away from the heat generated by the
cooktop.
INSTALL COOKTOP
All Units
1. Align the cooktop with the downdraft and fasten cooktop in
place.
Note: Accurate alignment of cooktop and downdraft is necessary
to ensure that there is no interference when air vent is raised and
lowered. There should be a gap of 1/32" - 1/16" between the back
of the cooktop and the front of the downdraft cover.
N
W
O
/ D
P
U
8
Exterior Blower Installation
CAUTION: All electrical wiring should be done
!
by a qualified person(s) in accordance with all
applicable codes and standards.
1. Mount a standard wiring box, with 3-pronged grounded recepta-
cle, inside the kitchen cabinet. Make sure the downdraft's power
cord can easily reach it.
2. Run appropriate power cabinet into cabinet and connect it to
electrical box and receptacle.
3. Exterior blower may not exceed 6.0 Amp rating.
4. Run 2-wire plus ground power cable from the remote blower
to wiring box on 10" round discharge plate.
5. Connect downdraft wiring to power cable from remote blower.
Wire black to black, white to white, and green to green or bare
wire.
6. Replace wiring box cover.
7. Plug the downdraft's power cord into outlet. Make sure that
the power cord is routed away from the heat generated by the
cooktop.
RANGETOP
Note:
Rangetops and Designer Cooktops must be used with an "R"
model downdraft (with remote control) - mounted into the
countertop, at least 4" from the burners.
Downdraft Ventilators
"R" MODEL
DOWNDRAFT
REMOTE
CONTROL
COUNTERTOP