Temperature Monitoring; Troubleshooting; Warranty - Oki PCT-1000 Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

All manuals and user guides at all-guides.com
6.
To decrease the zone time, press the footswitch at the desired time. This will
set the time to memory and advance the profile into the next zone.*
7.
Once required changes have been made, allow the profile to finish. Press and
hold (↵), until the LCD tops flashing, to set the profile to memory and exit
setup mode.
*Note: feature not available in Cool-Down Zone
4.4

Temperature Monitoring

1.
While using the PCT-1000 with the internal thermocouple (INT see Figure. 2
above), the two external thermocouples may be used to monitor temperature.
2.
Attach a thermocouple to TC1 and/or TC2 and attach to the area to be
monitored. When attached, the appropriate thermocouple will be displayed
(see Figure 3 above).
4.5
Advanced User Information
1.
When using the TC: TC1 option, consult the Advanced User Guide for
additional application information.

5. Troubleshooting

a.
Unit does not power ON
Check the power cord
Check to see that you have mains voltage
b.
OH displayed on the LED screen
Unit has exceeded the internal safety cut-off
Allow unit to cool
Check placement of thermocouple (if used)
Reset the unit by cycling the power
Review program, consult Advanced Users Guide.
c.
TCFAULT displayed on LED screen
Check location of thermocouple
Ensure the thermocouple is firmly inserted into the correct TC
connector
Replace thermocouple if problem persists
d.
Flashing zone and temperature parameters while in Run Mode.
Indicates the unit can not meet the programmed time and
temperature as set.
Review program, consult Advanced User Guide.
If you cannot resolve the problem after conformation of the above, please contact your
local OK International representative.

6. Warranty

Please visit OK International's products web page (www.okinternational.com) where you
will find available information on systems, tips, accessories, technical notes, and more.
You may also contact your local OK International representative for pricing and
availability.
OK International warrants the PCT-1000 programmable Preheater against any defects in
materials or workmanship for one (1) year from the date of purchase by the original
owner. This Warranty excludes normal maintenance and shall not apply to any opened,
misused, abused, altered or damaged items. If the product should become defective
within the warranty period, OK International will repair or replace it free of charge at its
sole option. The replacement item(s) will be shipped, freight prepaid, to the original
purchaser. The warranty period will start from the date of purchase. If the date of
purchase cannot be substantiated the date of manufacture will be used as the start of
the warranty period.