Descargar Imprimir esta página

How To Correct Problems In The Machine - Alto CLARKE ErgoEX IMAGE 16i Libro De Instrucciones

Inyector-extractor para la limpieza de alfombras

Publicidad

HOW TO CORRECT PROBLEMS IN THE MACHINE

PROBLEM
The machine will not run.
There is no suction.
Uneven or no spray from the
jets.
The drain valve leaks.
The solution pump runs
but no solution comes out
of the spray nozzle.
The solution pump leaks.
The float switch may not
be shutting off or turning on.
Brush motor doesn't run.
Page 36
CAUSE
1. Machine does not have power...
1. Vacuum motor may not be running...
2. Vacuum/accessory motor switch may
be defective.
3. There may be a loose motor
connection..
4. There may be an obstruction in the
vacuum hose....
5.
Motor brushes may be worn...
6. Drain valve may be open...
7. Dome gasket may be worn or
damaged...
8. Vacuum hose may be damaged...
9. Vacuum intake screen clogged...
1. The spray/brush switch may be
defective...
2. The spray tips may be dirty, plugged or 2. Clean or replace the tips
worn...
3. The hose may be kinked...
1. The drain valve gaskets may be worn
or damaged...
2. There may be lint or dirt in the drain
valve...
1. The spray tips may be plugged...
2. The spray solenoid may be damaged.
3. The solution screen may be plugged...
4. The pump may be worn...
5. The hose may be kinked...
1. There may be a faulty seal in the pump.. 1. Contact an authorized service person.
2. The pump may be worn...
1. The switch may be damaged...
1. Circuit breaker tripped...
2. Switch is bad...
3. Motor is bad....
ACTION
1. Make sure the machine is connected to
the correct frequency and voltage, and
all connections are tight.
1. Be sure the vacuum/accessory switch for
the vacuum motor is at the "ON" position.
2. Contact an authorized service person.
3. Contact an authorized service person.
4. Remove the obstruction.
5. Replace the motor brushes.
6. Close the drain valve.
7. Replace the gasket.
8. Replace the hose.
9. Remove and clean lint screen on vacuum
stand pipe.
1. Turn the switch to "I".
3. Inspect the hose.
1. Replace the gaskets.
2. Clean or replace the drain valve.
1. Clean the spray tips.
2. Replace spray solenoid.
3. Clean or replace the nozzle.
4. Contact an authorized service person.
5. Inspect the hose.
2. Contact an authorized service person.
1. Contact an authorized service person.
1. Reset circuit breaker.
2. Contact an authorized service person.
3. Contact an authorized service person.
CLARKE TECHNOLOGY Image 16 230V Operator's Manual

Publicidad

loading

Este manual también es adecuado para:

Clarke ergoex image 16ixErgo ex image 20iErgo ex image 20ix