Drawers:
To remove the Drawers on the drawer models for cleaning, simply open them fully, push the stop levers out of the way on the
Cabinet Drawer Tracks while pulling the Drawer out. To reinstall the Drawer, line up the Drawer Tracks on the cabinet and the
Drawer and push the Drawer into the cabinet. The Drawer Pan can be removed by lifting it out with the Drawer extended.
Electrical Connections:
Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to a power
source. The specifications on the data plate supersede any future discussion.
The standard unit is equipped with an eight (8) foot power cord that requires a 115 Volt, 60 Cycle, 1 Phase properly grounded
electrical receptacle. The power cord comes with a 3 prong plug for grounding purposes. Any attempt to cut off the grounding
spike or to connect to an ungrounded adapter plug will void the warranty, terminate the manufacturers responsibility and could result
in serious injury.
The circuit must be protected with a 15 or 20 ampere fuse or breaker. The unit must be isolated on a circuit and not plugged into an
extension cord.
OPERATION
Initial Start Up:
After satisfying the installation requirements, the unit is ready to start. The unit will start when the power cord is connected to the
required power source. If the compressor does not start when the unit is initially plugged in, check to make sure that the
temperature control is not in the 'off' position. Allow the unit to run a minimum of two hours before loading it with product. When
loading the unit with product, take care not to block the air flow at the back of the cabinet as this would affect the performance of the
cabinet.
Temperature Control:
The Temperature Control is located on the back wall of the cabinet liner and is factory set to maintain an average cabinet
temperature of 0 Deg. F. To obtain colder temperatures turn the Temperature Control stem clockwise and visa versa with a flat
blade screwdriver. Allow the unit a minimum of one hour to respond to a control setting adjustment.
Defrost:
Your Silver King unit is an automatic defrost unit. No additional plumbing is required. Automatic defrosting is accomplished by a
defrost heater and timer. Frost buildup on the evaporator coil is cleared at six hour intervals. Defrost water is collected in a pan
located in the compressor compartment where it is evaporated into the room air. It is important that the unit be level so the
condensate can drain properly.
MAINTENANCE
Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of
the appliance.
Cabinet Surfaces:
The cabinet interior and exterior are stainless steel. These surfaces should be cleaned periodically with a solution of warm water
and mild soap. After cleaning the surfaces should be rinsed with clean water and wiped dry with a soft cloth. Stainless steel
cleaners can also be used. Should a surface become stained, do not attempt to clean with an abrasive cleaner or scouring pad.
Use a soft cleanser and rub with the grain of the metal to avoid scratching the surface. Always rinse well and dry after cleaning.
Do not use chlorinated cleaners.
Condenser
Periodically, accumulated dust must be removed from the condenser. First, disconnect the unit from the
power supply. To clear the dust, vacuum or brush the condenser at the rear of the cabinet. This will need
to be done regularly to maintain the compressor warranty!
Door Gasket
The Door Gasket will collect dirt and should be wiped clean with a warm, mild soapy water solution to extend its life and assure
maximum cabinet performance and life.