Descargar Imprimir esta página

ARVA 3 Axes Modo De Empleo página 13

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

blocking function (masking) of the victim in the vicinity
Note: This method is one of the options for resolving the situation.
1
2
≥3
Begin your primary search if necessary...
- In the secondary search phase, if the device detects a multi-victim situation, the lamp
device has detected several transmitters around you.
- Then continue your search, following the standard method for a single buried victim.
- The device will automatically lock onto the device emitting the signal which is the strongest, and therefore theoretically
the victim closest to you. You have found the first victim (v1); locate the person with your avalanche probe and mark
how they lie.
You can therefore switch the device to the BLOCKING function. In order to switch the device, quickly activate selector
2
into the emitting position followed by the receiving position. As soon as you are in BLOCKING mode, the sound cuts
out and only CE appears on the screen for 3 seconds. The device's software 'blocks' the signal in the vicinity (that of
the victim discovered) and gives you the next signal received with a distance and direction.
Example:
• Having located victim V1, the device indicates via pictogram
• Remain level with the discovered victim V1 and quickly activate the emitting/receiving selector. You are then in
BLOCKING mode. The device continuously displays CE for 3s and then gives you a distance and a direction for the
next victim. The signal of victim V1 is masked temporarily.
• Travel in the new direction indicated to locate the signal of victim V2.
• Once the device has honed in on victim V2, the device displays CE again AND all directional diodes are switched on
simultaneously: this means that your device has indeed honed in its reception on the new signal
• When you reach victim V2, 3 little points appear under the multiple victims icon
at least a third signal around you. Mark the signals one by one.
• Once this device has honed in on the new signal, it operates in the standard way for a single victim buried. Operate
in secondary and final search if necessary.
N.B: The BLOCKING function (or masking) operates when the buried devices are dissociated one from another in terms
of emission. One device may conceal another. Ensure that you control the whole of the avalanche.
If, having activated the BLOCKING function, your device leads you back to the first victim V1, repeat the procedure. This
means that the device has not honed in its signal on V2.
If CE is still displayed without giving directions, remove from V1 location and repeat the procedure with the emitting/
receiving button.
Notice3axes2008.indd 13
Notice3axes2008.indd 13
v1
that a multiple burial scenario is present.
english
v2
6
will light up, meaning your
This means that the device detects
v3
G
29/07/08 9:04:44
29/07/08 9:04:44

Publicidad

loading