Publicidad

Idiomas disponibles

Idiomas disponibles

®
StableTemp
Digital Hotplates, and Stirring
Hotplates
Description
Digital Hotplate
Digital Hotplate with Probe
Digital Hotplate
Digital Hotplate with Probe
Stirrer Hotplate
Stirrer Hotplate with Probe
Stirrer Hotplate
Stirrer Hotplate with Probe
230V units are CE approved and have a Continental European plug. 120V
units operate on 60 Herz and 230V models operate on 50 Hertz.
Introduction:
Your Cole-Parmer Instrument Company hotplate or stirring hotplate is a general
purpose heating and/or stirring device intended for general indoor laboratory
procedures. The unit is available as a stirrer , hotplate, or stirring hotplate.
(Although the unit is available in three different configurations, the operation of
the heat and stir controls remains the same.
Heat and stir speed are accurately controlled to maintain the set temperature and
stirring speed. Heat and stir speed are easily set by simple controls on the front
panel. Temperature can be precisely set in 1 degree increments between 30°C
(86°F) and 550°C (1022°F). Temperature can be displayed in degrees Centigrade
or Fahrenheit. Both set and actual temperature are displayed. During operation
and after the heat is turned off, the hot top indicator lights if the top is too hot to
touch (>40°C/104°F).
An optional immersion probe allows direct, precise control of the temperature
from inside the solution. This chemical-resistant probe can be used to monitor
actual solution temperature when stirring temperature-sensitive samples. A
standard support rod can be attached to the unit for mounting the temperature
probe, as well as a thermometer, electrode, or buret.
Stirrer speed can be set in 1 RPM increments between 60 and 1200 RPM
(revolutions per minute). The unit automatically adjusts motor strength to
accommodate aqueous, viscous, or semi-solid solutions. Set and actual stir speed
are displayed. Included with stirring units is a 5/16-inch diameter by 2 inch long
(0.8 x 5.1 cm) Teflon-coated stir bar.
The unit ceramic top plate that measures 7x7 inches. The ceramic top stays flat
even at maximum temperature for uniform heating. The ceramic top also resists
acids and alkalis, and is easy to clean. Its reflective white surface allows easy
visualization of contrasts within the sample. The unit's rugged cast-aluminum
base enhances its stability on the bench top. The overall low-profile design
makes the unit easy to use in a hood.
Note: Use vessels with flat bottoms for the best heat transfer. Avoid metal
containers, sandbaths, or vessels with a rim around the bottom as these could
damage the ceramic top plate.
Symbols:
The following symbols are used in these instructions and on the device:
Indicates that user must read and understand the instructions.
Indicates that the surfaces may be hot.
Voltage
Amps
Cat#
04808-00
120V
7.4A
04808-10
120V
7.4A
04808-05
230V
4.1A
04808-15
230V
4.1A
04808-30
120V
7.5A
04808-40
120V
7.5A
04808-35
230V
4.2A
04808-45
230V
4.2A
Indicates a shock hazard from dangerous voltage.
Safety Information:
The equipment must be used as described in this manual. If used in a manner
other than described in this manual, protection provided by the device may be
impaired.
User must completely read, understand, and follow the instructions in this
manual before operating this equipment. This equipment is for indoor use only.
Your stirrer, hotplate, or stirring hotplate has been designed with function,
reliability, and safety in mind. It is the user's responsibility to install it in
conformance with local electrical codes.
To Avoid Electrical Shock, always:
1.
Use a properly grounded electrical outlet of correct voltage and current
handling capacity.
2.
Disconnect from the power supply prior to maintenance and servicing.
To Avoid Personal Injury:
1.
Do not use in the presence of flammable or combustible materials; fire or
explosion may result. This device contains components which may ignite
such materials.
2.
Space unit at least 6 inches away from any combustible materials under all
conditions.
3.
Use caution when heating volatile materials; top surface and element can
reach the flash point temperature of many chemicals. These hot plates and
stirring hot plates are not explosion proof. Fire or explosion may result.
Unit contains components which may ignite such materials.
4.
Keep top surface clean. Use a non-abrasive cleaner. Alkali spills,
hydrofluoric acid spills or phosphoric acid spills may damage top and lead
to thermal failure. Unplug unit and remove spills promptly. Do not
immerse unit for cleaning.
5.
Replace the top immediately if damaged by etching, scratching or chipping.
A damaged top can break in use.
6.
DO NOT USE METAL FOILS OR CONTAINERS, INSULATING
MATERIALS (e.g. sand baths), or LOW MELTING POINT GLASS (e.g.
soda lime glass) CONTAINERS on hotplate. Ceramic plate can be
damaged creating shock hazard.
7.
Do not remove or modify grounded power plug. Use only properly
grounded outlets to avoid shock hazard. Not rated for use in hazardous
atmospheres.
8.
Use appropriate hand and eye protection when handling hot containers
and/or hazardous chemicals.
9.
Unit should set on a dry surface. Do not set in a puddle of liquid.
10. Refer servicing to qualified personnel.
WARNING:
This product contains refractory fiber, insulation which can produce respirable
fibers and dust when unit is disassembled. These fibers or dusts can cause
irritation and can aggravate pre-existing respiratory disease. The insulating
materials are located in the top plate assembly. There may be a risk of exposure
to respirable dusts or fibers when repairing or maintaining the insulating
materials in a manner which causes the release of dust or fibers. Refer servicing
to qualified personnel.
Qualified personnel should consult the appropriate Material Safety Data Sheets
(MSDS's) for such products with respect to proper handling and appropriate
protective equipment..
Note: This unit contains materials which may emit a slight odor or smoke during
initial operation. This will dissipate within an hour and will not affect the
operation or performance of the hotplate.
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Cole-Parmer StableTemp 04808-00

  • Página 1 This device contains components which may ignite such materials. Your Cole-Parmer Instrument Company hotplate or stirring hotplate is a general Space unit at least 6 inches away from any combustible materials under all purpose heating and/or stirring device intended for general indoor laboratory conditions.
  • Página 2: Environmental Requirements

    It will accommodate rods up to 0.5” Plate and Probe Indicators: Show whether temperature being (13mm) diameter. Accessories are available from Cole-Parmer (in displayed is being measured at the top plate or through the optional the catalog under the Flexaframe and Castaloy sections) for this unit.
  • Página 3: Troubleshooting

    Replace the bad fuses. Slide the holder firmly back into the IEC module. Reconnect the cord. CAUTION: Double pole neutral fusing (230V units only). Instruction Part # 105793 Rev. A 1-800-323-4340 Cole-Parmer Instrument Co., www.coleparmer.com 625 East Bunker Court, Vernon Hills, IL 60061...
  • Página 4 Voltage Cat# Cat# Amps Plaque chauffante Agitateur chauffant Note: Cole-Parmer Scientific reserves the right to change product design or specifications without notice or obligation. 120V 0408-00 0408-30 7.4A / 7.5A 230V CE...
  • Página 5 10. L'entretien doit toujours être effectué par le personnel qualifié. Commande d’agitation (Stir) : Permet de mettre en marche et d’arrêter la AVERTISSEMENT: fonction agitation. Instruction Part # 105793 Rev. A 1-800-323-4340 Cole-Parmer Instrument Co., www.coleparmer.com 625 East Bunker Court, Vernon Hills, IL 60061...
  • Página 6 Ce support peut être équipé d’une tige d’un diamètre de 13 1. Avant d'utiliser l'appareil, veillez à lire, comprendre et suivre tous les mm. Les accessoires de cet appareil sont disponibles chez Cole-Parmer conseils de sécurité contenus dans ces instructions.
  • Página 7 Appuyez sur la touche de commande du chauffage chauffant. (Heat) pour que le voyant lumineux s'allume. A NOTER: Cole-Parmer se réserve le droit de modifier la conception ou les caractéristiques de ses produits sans notification ni engagement. Pas d'agitation Appuyez sur le bouton de commande de l'agitateur pour que le voyant lumineux s'allume.
  • Página 8: Introducción

    Es La Agitadora, la Placa Calentadora y la Placa Agitadora/Calentadora responsabilidad del usuario que la instalación sea conforme a los Cole-Parmer Stable Temp son instrumentos manufacturados para uso códigos de electricidad locales. general interno en procedimientos de laboratorio.
  • Página 9: Para Evitar Lesiones Personales

    Operación: Temperatura del ambiente: 10-40°C Humedad Relativa: 0 a 90% (no-condensada) Instruction Part # 105793 Rev. A 1-800-323-4340 Cole-Parmer Instrument Co., www.coleparmer.com 625 East Bunker Court, Vernon Hills, IL 60061...
  • Página 10 El sostenedor recibe varillas de hasta 0.5” (13mm) de acoplamiento. diámetro. Los accesorios para este aparato están disponibles por medio de Cole-Parmer (en el catálogo en la sección bajo el nombre de Para establecer la temperatura deseada, oprima el botón Flexaframe y Castaloy.) Heat (botón de calor) de manera que el indicador de calor...
  • Página 11: Limpieza

    Oprima el botón Stir (Agitación) de manera que el Indicador de agitación se encienda Si los problemas persisten, solicite servicio técnico llamando a: Instruction Part # 105793 Rev. A 1-800-323-4340 Cole-Parmer Instrument Co., www.coleparmer.com 625 East Bunker Court, Vernon Hills, IL 60061...
  • Página 12: Lista De Partes De Reposición

    Use únicamente partes y accesorios originales Cole-Parmer Scientific diseñados específicamente para sus Agitadores, Placas Calentadoras y Placas Agitadoras/Calentadoras. Nota: Cole-Parmer se reserva el derecho para cambiar el diseño o las especificaciones de sus maquinas sin previo aviso u obligación. Calentador, 120V...

Tabla de contenido