Beretta ALPHA DGT Manual De Instalacion Y Uso página 3

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
THESE INSTRUCTIONS ARE TO BE RETAINED BY THE USER
Thank you for choosing this radio frequency (RF) radiostat. This cen-
tral heating control device is easy to fit, and with correct use, will de-
liver improved comfort levels in your home whilst saving you money.
This thermostat is designed to be used only with heating controls
system with a maximum switching load of 2A at 30VDC or 0,25A
at 230VAC (relay specifications of the boiler room thermostat
connection).
If installing for someone else, please ensure that the instructions are
handed to the householder.
WARNING: Please read this manual prior to installation or use.
SHOCK HAZARD: This unit must be installed by a competent per-
son, in accordance with BS 7671 (the IEE Wiring Regulations), or
other relevant national regulations and codes of good practice. Al-
ways isolate the AC Mains supply before installing this unit.
FIRST INSTALLATION WARNING: The product arrives with most
of the parameters factory set with minimal actions required by the
installer: wiring connections of the receiver to the boiler, setting the
time and setting the day. All the rest, like coupling between receiver
and transmitter, heating pattern, default temperatures, etc. are al-
ready pre-configured at the factory.
IMPORTANT: these instructions should be read in conjunction with
the appliance installation instructions. It is recommended that this
device is installed by a qualified electrician.
ENCODER KNOB
Encoder movements: clockwise and anticlockwise rota-
tion, push to select.
Encoder clockwise and anticlockwise rotation: in-
crease or decrease the room comfort temperature, auto
enter of the selected value after 5 seconds.
Encoder rotation one step: check the selected comfort tempera-
ture. The value will blink for few times and later it will be back to the
room temperature value display.
Press and hold the encoder once to ativate or de-ativate the AD-
VANCE function (only if set in AUTO mode).
Press and hold the encoder longer for enter in menu and select
the status mode or set the time/programming/parameters (see spe-
cific paragraph).
DISPLAY
ENCODER
SENSOR OPENING
LCD DISPLAY
SYMBOL DESCRIPTION/FUNCTION
Heating mode is active (winter mode).
AUTO: the thermostat uses the programmed heating
pattern (default or user defined) to switch the heating
ON & OFF at preselected times.
OFF: the thermostat is set to have the heating con-
stantly OFF (in this mode the default or user defined
heating pattern is ignored) – summer mode.
PARTY: the thermostat is set to provide heating con-
stantly ON (in this mode the default or user defined
heating pattern is ignored). This status stay ON up to
end user switching OFF
ADVANCE: the pre-programmed heating pattern is
advanced to the next ON (or OFF) period (this function
can only be used when the clock is in the AUTO mode)
Used to show current day of week
Used to show current time of day or explanation inside
the main menu
24-hour clock in 60 minute segments. Side example:
The heating fascia is OFF up to 15:59 and it is ON from
16:00 to 18:59
Used to show current room temperature or desired
temperature to be selected.
Batteries low
Heat request to the boiler (central heating ON)
Other icons inside the main menu:
SYMBOL
EC O Ł
I - -S
P L
E H I Ł
QUICK START GUIDE
To be read and used after a proper installation has been made and after
the hours and the working mode has been set.
WORKING MODE: This central heating control device provides you
both the room thermostat function and the weekly clock function.
When in AUTO mode, the central heating will be ON/OFF according
to the programmed times and according to the set comfort temper-
ature (the ON command is identified by the flame icon). When the
heating will be commanded ON the set-point in the room will be the
comfort one. In case of off programmed times, the set temperature is
the "economy temperature", selectable inside the main menu (16°C
is the default value).
When in OFF mode the heating requested will be switched on when
the room temperature drops under the frost protection value (default
is 5°C); this value can be modified inside the technical menu.
When in PARTY mode the heating request is permanently on ac-
cording the selected comfort temperature that can be modified any
time rotating the encoder and pressing to confirm.
ENCODER
The encoder has three functions: selection of the set temperature,
set the ADVANCE function and setting the thermostat. If the status
mode of the thermostat is OFF, only the pressing functionality is ac-
tive; any rotation done does not generate any modification.
1. Rotate to select the desired temperature and press to enter. The
rotation of 1 step of the encoder shows on display the selected
"comfort" temperature value.
2. Press once to ativate or deativate the ADVANCE function. Use to
"advance" the heating to an ON or OFF period (only if set in AUTO
mode).
3. Press for 3 seconds to enter menu. Rotate to scroll through the
menu choosing between status mode, economy temperature set-
ting, heating and cooling mode, time of day, day of the week, pro-
grammed times day by day, technical menu (PL) and exit.
Press again to modify selected item.
3
DESCRIPTION/FUNCTION
Economy temperature selection
Heating or Cooling mode
selection (factory set in heating)
Technical menu selection
(only for expertise)
Escape from main menu

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido