Setup System; Setup Codes - JCM ACCESS - 1000 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1

1- SETUP SYSTEM

Allows for the following to be configured: date/time, relays, channels and language.
1.1 DATE&TIME
1.2 RELAYS
1.3 CHANNELS
1.4 LANGUAGE
1.1 DATE&TIME
This allows for the date and the time to be configured in the controller for correct event management and expiry date management.
Enter the date and time using the numeric keys. If no modifications are to be made, press ESC.
If no action is made, the equipment will automatically exit programming after 60 seconds and two short sound signals are given.
1.2 RELAYS
This allows for the relay enabling timer and anti-panic function on each independent relay to be configured.
Relays
Pulsed
1 / 2 / 3 / 4
01-30 seconds
If no action is made, the equipment will automatically exit programming after 60 seconds and two short sound signals are given.
1.3 CHANNELS
Allows for a specific relay or relays to be configured for enabling with each channel.
Factory configuration is: Channel 1 enables relay 1, channel 2 enables relay 2, channel 3 enables relay 3 and channel 4 enables
relay 4.
Example: If channel 1 of the transmitter is to be configured to enable relays 1 and 3, numbers 1 and 3, selected using the numeric
keys, must be displayed on the screen.
Every time a numeric key is pressed the required relay is enabled or disabled.
To exit the menu, press ESC.
The configuration chosen for each channel will be programmed into the controller.
If no action is made, the equipment will automatically exit programming after 60 seconds and two short sound signals are given.
1.4 LANGUAGE
This allows for the required language to be selected. This is Spanish by default.
1- ESPAÑOL
2- FRANÇAIS
3- ENGLISH
If no action is made, the equipment will automatically exit programming after 60 seconds and two short sound signals are given.

2- SETUP CODES

Allows for registrations, cancellations, killpass and discounts to be made
2.1 ADD CODES
2.2 DEL CODES
2.3 KILLPASS
2.4 PRE-PAY
2.1 ADD CODES
Allows for individual and sequential registrations to be made
2.1.1 SINGLE
a) Indicating position and code
Enter the position number required and press INTRO. Enter the code number to be programmed and press INTRO. The controller
will issue a sound signal indicating that the operation has been successfully completed.
Biestable
Antipanic
Yes
01-15 minutes
20