JCM ACCESS - 1000 Manual Del Usuario página 23

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
2.4 PRE-PAY
This allows for units on a proximity element with pre-payment function to be discounted (maximum 65535 units).
Pre-payment Function
In the pre-payment function, users have a proximity element allocated, following payment (of a certain number of units), using
the Assistant programming tool.
The units to be discounted every time users pass their proximity element in front of a reader are programmed into the controller.
Each reader can discount a different number of units. Users can use the proximity element while it is in credit. When the credit
is used up it can be recharged.
On receiving a code with the pre-payment function programmed, the controller activates the corresponding output and discounts
the units previously allocated to that channel (one unit is discounted by default). If more units are to be discounted than those
available, the controller will remain motionless and the message "NO CREDIT" will appear on the screen.
Configuration
The proximity elements with the pre-payment function must be registered in the controller using the numeric keys to enter the
PRE-PAYMENT PIN number instead of the code in the registration menu. The factory-issued PRE-PAYMENT PIN number is the
same for all devices (000000). Use the Assistant programming tool to modify this number individually.
Enter the required channel and press INTRO. Enter the number to be discounted (maximum 4 digits) and press INTRO. The
controller will issue a sound signal to indicate that the operation is being carried out. OK will appear on the screen.
If no action is made, the equipment will automatically exit programming after 60 seconds and two short sound signals are
given.
3- SETUP APB
Allows for the anti-passback timer to be configured and reset.
3.1 APB CONF
Select the operating mode and press INTRO.
MODE
Function
MODE 0
Anti-passback disabled
MODE 1
Anti-passback for single-channel devices and a single door (entry and exit)
MODE 2
Anti-passback for dual-channel devices and two doors (one entry and another exit)
Select the anti-passback enabling time and press INTRO.
TIME
Function
0
Absolute anti-passback
1-60 minutes
Anti-timeback
3.2 RESET APB
Press INTRO and the controller will reset the anti-passback. Once reset has been completed, the anti-passback is initialised and
access is allowed in either direction (entry or exit), thus re-enabling the anti-passback individually for each user.
In the event of the controller power supply being cut off, the anti-passback is automatically reset.
If a user accesses for a second consecutive time in the same direction, the controller will remain motionless and the message "NO
APB" will appear on the screen.
If no action is made, the equipment will automatically exit programming after 60 seconds and two short sound signals are given.
23

Publicidad

Tabla de contenido
loading

Tabla de contenido