INSTALLATION
Install inside of the fixture and to mount it up to the center of the frame (you see figure), with the lens
of a valve turned towards the low.
Open the detector and set the base with two screws.
Make the connections (see under).
Close the cover and screw to bottom for assures the fixed of the circuit.
Do not install the detector near sources of heat (example: electric radiators, heaters, air
conditioners, flames, etc.)
Do not partially or completely obscure the field of view of the detector.
Also avoid the installation of shutters and internal frame.
Microwave
section
(only DT8)
IR8 - DT8
Pulses-count
(Only DT8)
The clamp M can be connected to the + INT of central alarm if you want to activate the alarm memory
function, otherwise it should be left unconnected.
WARNING: Do not touch the pyroelectric sensor with your fingers!
6
Adjustable
sensitivity
PIR
Sensor
Switch
(only for those hatched DT8)
NC
TAMPER
Operation LED