automatically resetting when the voltage drops back to 130 volts. If the incoming voltage drops below 90
volts, the T200 will shut down, automatically resetting when until the voltage returns to 95 volts.
FRONT PANEL CIRCUIT BREAKER
If the T200 experiences an incoming current in excess of 15A, the front panel circuit BREAKER will
disconnect the mains power. To reset the BREAKER simply push it in.
USB OUTLETS
Two USB multi-purpose outlets, one on the front panel and one on the rear panel, are designed for
charging compatible cell phones, iPods or any other device designed with a USB connector. They can also
be used for powering the included USB light. Made with a 12" gooseneck, the USB light is terminated with
a USB connector and is fitted with a small magnetic plate. The lamp may be plugged into the front or rear
USB connector and used to illuminate the front or rear of the components. The magnetic plate makes it
easy to store the lamp when not in use.
EXTERNAL DC POWER-ON TRIGGER
This feature enables the remote turn-on of the T200 Power Manager by a component providing a 3-12
volt trigger output. A TRIGGER IN 3.5mm jack is provided as well as a TRIGGER OUT 3.5mm jack for daisy
chaining a second Tributaries Power Manager. The TRIGGER OUT provides the capability to turn-on another
power product that has a trigger input.
FRONT PANEL INDICATORS OF OUTLET STATUS
The blue LEDs provided on the front and rear panels of the T200 indicate status and timing of the
SWITCHED, DELAYED, ALWAYS-ON outlets as well as for the status of the surge suppression electronics
(PROTECTED) and grounding circuits (GROUNDED). A red LED (POLARITY FAULT) will illuminate if the wiring
of the outlet into which the T200 is plugged is faulty (see below).
LED DIMMER CONTROL
A retractable LED DIMMER control is located on the front panel. Rotating the control clockwise increases
the LED's brightness and counterclockwise rotation dims them. Please note; to comply with UL® standards,
the LEDs can't be turned off completely. To store the control, push it in until the locking mechanism
engages. To release it, push it in.
POWER SWITCH
To prevent inadvertent turn on or turn off, the front panel POWER switch must be depressed for at least 2
seconds.
POLARITY IDENTIFICATION
Polarity Identification is provided to guarantee that the AC outlet the T200 is plugged into is wired
correctly. The illumination of the blue POLARITY FAULT LED indicates that the White and Black AC wires of
the outlet into which the T200 is connected are reversed.
DO NOT OPERATE YOUR T200 WITH A LINE PROBLEM. IF THE RED POLARITY FAULT LED DOES
!
ILLUMINATE, DISCONNECT THE UNIT IMMEDIATELY. A LICENSED ELECTRICIAN WILL NEED TO
REPAIR THE FAULTY WIRING PRIOR TO RECONNECTING THE T200.
ETL Listings
Your T200 has been exhaustively tested by Intertek and bears the ETL Listings mark). This ensures the
product is safe when operated according to these instructions. The T200 has been certified for:
UL 1449: Standard for Transient Voltage Surge Suppressors
UL 1363: Standard for Relocatable Power Taps
UL 61010-1: General safety requirement for USB charger
UL 60950: Protection for DATA Processing equipment (RJ11 & RJ45)
UL1283: Electromagnetic Interference Filters for 50/60Hz equipment
6