INSTALLATION
MOUNTING THE UNIT
INSTALLATION
4. Mounting the unit
8
1
1 Electrical junction box
2 Water supply line for faucet installation
3 3/8" compression-T
4 Shut-off valve
5 1/2" main pipe
6 Sink
7 Cold valve (right)
8 Hot valve (left)
DANGER Electrocution
UNIT MUST BE INSTALLED IN A VERTICAL POSITION
WITH THE WATER FITTINGS POINTING DOWNWARD.
DO NOT INSTALL UNIT WHERE IT WOULD ROUTINELY
BE SPLASHED WITH WATER. ELECTRIC SHOCK MAY
RESULT.
1. Install AQC as close as possible to the hot water draw-off
point, for example, directly underneath the sink or next to
the shower stall.
2. Install AQC in a frost free area. If frost may occur, remove
unit before freezing temperatures set in.
3. Leave a minimum of 5" of clearance on all sides for
servicing.
4. Remove plastic cover.
4
| AQC TANKLESS ELECTRIC WATER HEATERS
7
5. Mount unit securely to wall by putting two screws through
6
mounting holes. Screws and plastic wall anchors for mount-
ing on masonry or wood are provided.
5
4
3
2
WWW.APTANKLESS.COM