Indicator "00:" is flashing.
To adjust interval OFF Time,
use the ▲ and ▼ buttons to set the hours between 0 and 23.
Press the
button, the minutes will flash - "30".
Use the ▲ and ▼ buttons to set the minutes between 30 and 59*.
Press
.
If you want to finish programming, press and hold
* Settings between 0 and 59 are only possible with intervals of 1 hour or longer. For shorter intervals, a minimum of
30 minutes is preset by the manufacturer to protect electronic components.
Note: The first interval control is triggered immediately after the system returns to operating mode.

6. Factory settings / Reset

Clock setting:
Temperature 1 (water heating):
Temperature 2 (floor heating/cooler) (differential to temperature 1):
Audible temperature alarm:
Visual temperature alarm:
Temperature mode:
Timer mode:
Should your Biotherm pro not function correctly, please perform a reset:
1. Unplug from mains
2. Plug the mains plug back in while keeping the
3. Release the
button
Attention: All programmed settings, except those for the clock, are lost. The Biotherm pro will regulate temperature
with factory's presettings (temperature 1 (water heating): 25° C / temperature 2 (floor heating/cooler): differential to
temperature 1: 0.1° C).
for 3 seconds until the display returns to operating mode.
12:00:00
25° C
0.1° C
deactivated (Beep off)
deactivated (00 means no alarm)
Heating
Aut (means 'automatic')
button pressed