THERMOSTATIC DRAFT REGU-
LATOR
"ENERGY plus" boilers are fitted with
thermostatic controllers.
NOTA:
In order to fix the lever with the chain-
let in the regulator holder it is neces-
sary to remove the deflector in alumi-
num, which is assembled on the control
board, by unscrewing the three screws
that fix it (12 fig. 6 - page. 11).
Replace the protection deflector after
the assembling and related adjust-
ment.
Regulator
The regulator is equipped with a ther-
mosetting resin knob (B fig. 8/9) of
an adjustment field from 30 to 90 °C
(fig. 8).
Screw the regulator on the 3/4" opening
of the anterior head and orientate the
red index on the upper part.
The lever with the chainlet should be
introduced in the regulator holder after
having assembled the instrument holder
board and after having removed the
plastic lock.
If the joint is taken out, which fixes
the lever with the chainlet, take care in
assembling it again in the same posi-
tion.
After having placed the knob at 60°C,
block the lever with the chainlet in a
slightly inclined position downwards,
so that the chainlet will be in axis with
the air gate damper.

HYDRAULIC CONNECTION DIAGRAM

Open expansion tank system
ENERGY PLUS
INSTALLATION
Regulator
Fig. 8
For the adjustment, which essentially
consists in the determination of the
chainlet length, proceed in the follow-
ing way:
– Place the knob at 60°C.
– Switch on the boiler with opened air
gate damper (C fig. 9).
– When the water temperature of 60° C
is reached in the boiler, fix the chain-
let in such a way on the lever (A fig.
9) of the air gate damper, in order to
obtain an opening of about 1 mm.
– Now the regulator is calibrated and it
is possible to choose the desired op-
erating temperature by rotating the
knob (B fig. 9).
VEA
- 12
-
instrument
holder board
C
Fig. 9
LE GEN D
V EA
Open expansion tank
V S
System safety valve 3 BAR - 1/2"
V M
Mixing valve
V R
Check valve
PI
System pump
IR
Heating system
B
B
A
Fig. 10